2025年05月29日 星期四 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2021, Vol. 42 Issue (4): 401-408    DOI: 10.3969/j.issn.1000-1158.2021.04.01
  电磁学计量 本期目录 | 过刊浏览 | 高级检索 |
一种基于三端口网络的互感器电压串联加法
周峰1,雷民1,王乐仁1,殷小东1,刘浩1,2
1. 中国电力科学研究院有限公司国家高电压计量站, 湖北武汉430074
2. 华中科技大学 电气与电子工程学院强电磁工程与新技术国家重点实验室,湖北 武汉 430074
A Transformer Voltage Series Method Based on Three-Port Network
ZHOU Feng1, LEI Min1, Wang Le-ren1, YIN Xiao-dong1, LIU Hao1,2
1.National Central for High Voltage Measurement of China, China Electric Power Research Institute,Wuhan, Hubei 430074, China
2. State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China
全文: PDF (1123 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 1954年Zin E和Forger K成功研究出互感器串并联电压加法线路;1988年国家高电压计量站成功研究出互感器双边串联电压加法线路,2006年使用串联型电压互感器进行双边电压加法,2008年试验电压达到1000/3kV,电压比不确定度不大于4×10-5(P=95%)。要进一步减小电压比的不确定度,需要最大限度地消除串联型电压互感器的屏蔽误差以及邻近干扰误差。除了设计电磁屏蔽更完善的串联型电压互感器外,还可以使用三端口网络理论实施电压加法,通过三端口网络的响应叠加性,使得在加法过程中的屏蔽误差和邻近干扰误差很大程度上得到补偿。2013年使用广东电网电力科学研究院的500kV工频电压比例自校系统装置进行了验证试验。与1988年数据相比,110/3kV电压下的屏蔽误差从18×10-6减小到1.5×10-6,与2006年数据相比,500/3kV电压比例不确定度从15×10-6减小到7×10-6(P=95%)。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
周峰
雷民
王乐仁
殷小东
刘浩
关键词 计量学高电压计量三端口网络电压串联加法串联型电压互感器电压比例标准    
Abstract:In 1954 Zinn E and Forger K researched series-parallel voltage summation circuit by employing voltage transformers successfully. In 1988 the National High Voltage Metering Station studied the bilateral series voltage summation circuit successfully. In 2006 the National High Voltage Metering Station employed series type voltage transformer for bilateral voltage summation. In 2008 the test voltage reached 1000/3kV and the uncertainty of voltage ratios was not more than 4×10-5(P=95%). In order to reduce the uncertainty of voltage ratio, it is necessary to eliminate the shielding error and proximity interference of the series type voltage transformer. In addition to design a series type voltage transformer with more perfect shielding structure for electromagnetic interference, the theory of three-port network could also be used to implement voltage summation. Following a certain test procedure the shielding error and proximity interference in the summation operation would be largely compensated by the response superposition of the three-port network. In 2013, the 500kV power frequency voltage proportional self calibration system of Guangdong Electric Power Research Institute was used for verification test. Compared with the data in 1988, the shielding error at 110/3kVdecreased from 18×10-6 to 1.5×10-6, and compared with the data in 2006 the uncertainty of ratio error at 500/3kV decreased from 15×10-6 to 7×10-6(P=95%).
Key wordsmetrology    high voltage measurement    three-port network    voltage series summation    series type voltage transformer    voltage ratio standard
收稿日期: 2019-03-21      发布日期: 2021-04-20
PACS:  TB971  
基金资助:国家电网公司科技项目(JL71-09-001)
通讯作者: 刘浩(1990-),男,湖南邵阳人,中国电力科学研究院工程师,华中科技大学在读博士研究生,研究方向为高电压计量方法。Email: liuhao1@epri.sgcc.com.cn     E-mail: lehren@163.com
作者简介: 周峰(1980-),男,湖北仙桃人,中国电力科学研究院教授级高工,博士,主要从事高电压计量方法方面的研究。Email: zhoufeng@epri.sgcc.com.cn
引用本文:   
周峰,雷民,王乐仁,殷小东,刘浩. 一种基于三端口网络的互感器电压串联加法[J]. 计量学报, 2021, 42(4): 401-408.
ZHOU Feng, LEI Min, Wang Le-ren, YIN Xiao-dong, LIU Hao. A Transformer Voltage Series Method Based on Three-Port Network. Acta Metrologica Sinica, 2021, 42(4): 401-408.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2021.04.01     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2021/V42/I4/401
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn