绝缘油介电强度测试仪在高电压行业有着广泛的应用,设备数量多,校验需求大,校验过程危险性大,特别是容易因为误操作造成人身伤害及设备损坏。目前国内缺乏专门为其设计的校验装置,为此特别设计了一款专用的校验装置,通过主动击穿模块、隔离保护模块、采样处理模块,分别在试验过程、安全保护和数据处理三个方面满足客户的校验需求。在保证校验安全的同时,增加对被校设备击穿过程的分析,进一步加强校验的准确性。
Abstract
Insulating Oil Dielectric Strength Tester has wide application for High voltage. There are many devices need to calibrate. The risk of the calibration process is large, and it is easy to cause personal injury and damage to the equipment caused by misuse.Domestic lack of specialized equipment. A special device is designed to guarantee the calibration process by the design of initiative breakdown module, protection module, sample processing module and to further strengthen the accuracy of the calibration.
关键词
计量学 /
绝缘油介电强度测试仪校验装置 /
主动击穿模块 /
隔离保护模块 /
采样处理模块
Key words
metrology /
calibration device of insulating oil dielectric strength tester /
initiative breakdown module /
protection module /
sample processing module
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
1 王斯琪,项琼,雷民. 绝缘油介电强度测试仪校验装置的研制[C]// 2008全国电工测试技术学术交流会. 2008:108-110 .
2 GB/16927.1—1997 高电压试验技术第一部分:一般试验要求[S].1997.
3 杨书贞. 电工理论[M]. 北京:中国科学技术大学出版社,1999:7.
4 中华人民共和国能源部. DL429.9—91 绝缘油介电强度测定法[S].
5 张乐.绝缘油介电强度测试仪校准关键技术研究[D].天津:天津大学, 2012.
6 潘洋,石雷兵,糜坚平,等.绝缘油介电强度测试仪电极电场计算及其校准方法研究[J].仪器仪表学报,2014,35(8):1831-1835. PanY, ShiL B, MiJ P, alet, Calibration of insulation oil tester output voltage based on the electric field calculation for the electrode structure[J]. Chinese Journal of Scientific Instrument, 2014,35 (8):1831-1835.
7 唐峰.关于变压器油击穿电压试验的几个问题[J].广东电力,2003,16(5):16-18. TangF. On breakdown voltage test of transformer oil[J]. Guangdong Electric Power, 2003,16(5):16-18.