Abstract:An AC power differential measurement system was designed based on the Josephson quantum voltage standard.By analyzing the error distribution and error transfer function of the differential sampling system, the sampling switching differential measurement method was proposed, which reduced the gain error of the differential sampling system and improved the accuracy of voltage amplitude measurement.By analyzing the attenuation coefficient η, it was proved that it is easy to realize voltage amplitude measurement of 10-7 magnitude by using switching differential measurement.By evaluating the zero phase of the differential sampling system, the results showed that the differential sampling system has better phase measurement stability.The uncertainty component of the AC power differential measurement system was analyzed, and the power measurement uncertainty of the power factor of 1.0, 0.5L and 0.5C was evaluated. Through the experimental comparison with the AC power national reference instrument, the rationality of the power measurement of the AC power measurement system based on Josephson quantum voltage was proved.
贾正森, 王磊, 徐熙彤, 周天地, 潘仙林, 石照民, 张江涛. 基于约瑟夫森量子电压的交流功率测量系统及方法研究[J]. 计量学报, 2020, 41(4): 469-474.
JIA Zheng-sen, WANG Lei, XU Xi-tong, ZHOU Tian-di, PAN Xian-lin, SHI Zhao-min, ZHANG Jiang-tao. Research on AC Power Measurement System and Method Based on Josephson Quantum Voltage. Acta Metrologica Sinica, 2020, 41(4): 469-474.
1 HamiltonC A, BurroughsC J, KautzR L. Josephson D/A converter with fundamental accuracy[J]. IEEE Trans Instrum Meas, 1995, 44, (2): 223-225.
2 BenzS P, HamiltonC A, BurroughsC J, et al. Stable 1 volt programmable voltage standard[J]. Appl Phys Lett, 1997,71(13): 1866-1868.
3 SchulzeH, BehrR, MüllerF, et al. Nb/Al/AlO/Al/ AlO/Al/Nb Josephson junctions for programmable voltage standards[J]. Appl Phys Lett, 1998, 73(7): 996-998.
4 RüfenachtA, BurroughsC J, BenzS P, et al. Precision differential sampling measurements of low-frequency synthesized sine waves with an AC programmable Josephson voltage standard[J]. IEEE Trans Instrum Meas, 2009, 58(4): 809-815.
5 BurroughsC J, BenzS P, DresselhausP D, et al. Development of a 60Hz power standard using SNS programmable Josephson voltage standards[J]. IEEE Trans Instrum Meas, 2007, 56(2): 89-294.
6 WaltripB C, GongB, NelsonT L, WangY., et al. AC power standard using a programmable Josephson voltage standard[J]. IEEE Trans Instrum Meas, 2009, 58(4): 1041-1048.
7 PalafoxL, RammG, BehrR, et al. Primary ac power standard based upon programmable Josephson junction arrays[J]. IEEE Trans Instrum Meas, 2007, 56(2): 534-537.
8 RufenachtA, BurroughsC J, BenzS P. Precision sampling measurement using AC programmable Josephson voltage standard[J]. Rev Sci Instrum, 2008, 79(4): 044704-1-044704-9.
9 BudovskyI, GeorgakopoulosD, HagenT, et al. Precision AC-DC difference measurement system based on a programmable Josephson voltage standard[J]. IEEE Trans Instrum Meas, 2011, 60(7): 1041-1048.
10 ChenS, AmagaiY, MaruyamaM, et al. Uncertainty evaluation of a 10V RMS sampling measurement system using the AC programmable Josephson voltage standard[J]. IEEE Trans Instrum Meas, 2015, 64(12): 3308-3314.
11 GeorgakopoulosD. Uncertainties in the measurement of AC voltage using a programmable Josephson voltage standard and a phase-sensitive null detector[J]. IEEE Trans Instrum Meas, 2011, 60(7): 2178-2183.
12 JiaZ S, LiuZ Y, WangL, et al. Design and implementation of differential AC voltage sampling system based on PJVS[J]. Measurement, 2018, 125: 606-611.
13 LuZ L, YangY, HuangL, et al. Further investigation for piecewise sampling to overcome transient effect of staircase waveform[J]. IEEE Trans Instrum Meas, 2017, 66(6): 1217-1226.
14 LuZ L, YangY, HuangL, et al. Further investigation for piecewise sampling to overcome transient effect of staircase waveform[C]// 2016 Conference on Precision Electromagnetic Measurements. Ottawa, Canada, 2016.
15 LuZ L. Discussion on new properties of staircase waveform through connection to an infinite series[J]. IET Sci Meas Technol, 2015, 9(1): 63-72.
16 陆祖良,杨雁,黄璐,等. 阶梯波性质的进一步探讨——阶梯波研究之一[J]. 计量学报, 2018, 39(6): 759-767. LuZ L, YangY, HuangL,et al.Further Discussion on Characteristics of Staircase Waveform[J].Acta Metrologica Sinica,2018, 39(6): 759-767.
17 陆祖良,杨雁,黄璐,等.片段采样与阶梯波测量——阶梯波研究之二[J].计量学报,2019,40(1):31-39. LuZ L, YangY, HuangL,et al.Piecewise Sampling and Measurement of Staircase Waveform[J].Acta Metrologica Sinica,2019, 40(1): 31-39.
18 陆祖良,杨雁,黄璐,等.正弦波电压差分测量与多周期策略——阶梯波研究之三[J]. 计量学报, 2019, 40(2): 319-328. LuZ L, YangY, HuangL,et al.Differential Measurement of Sine Wave Voltage and Multi-period Strategy[J].Acta Metrologica Sinica,2019, 40(2): 319-328.
19 陆祖良,杨雁,黄璐,等.基于阶梯波的周期非正弦电压精密测量——阶梯波研究之四[J]. 计量学报, 2019, 40(3): 481-490. LuZ L, YangY, HuangL,et al.Precision Measurement of Non-sinusoidal Voltage Based on Staircase Waveform[J].Acta Metrologica Sinica,2019, 40(3): 481-490.
20 ShiZ M, ZhangJ T, PanX L, et al. Self-calibration of the phase angle errors of RVDs at frequencies up to 100kHz[J]. IEEE Trans Instrum Meas, 2018, 67(3): 593-599.
21 JiaZ S, LiuZ Y, LiB, et al. Uncertainty evaluation of differential sampling system using AC programmable Josephson voltage standard[C]//Proc CPEM Dig.Paris,France, 2018.
22 OldhamN, NelsonT, ZhangN F, et al. CCEM-K5 Comparison of 50/60Hz Power[R]. Final Report,NIST, 2012.