Phase Volume Fraction Measurement of Gas-liquid Two-phase Flow Based on Near-infrared Surface Source Sensor
FANG Li-de1,2,3,WANG Shao-chong1,2,3,WANG Pei-pei1,2,3,WANG Song1,2,3,WANG Dong-xing1,2,3,ZHENG Qing-long4,LI Xiao-ting1,2,3
1. College of Quality and Technology Supervising, Hebei University, Baoding, Hebei 071000, China
2. Measuring Instruments and Systems Engineering Laboratory of Hebei Province, Baoding, Hebei 071000, China
3. The Center of Measuring Instruments and Systems Engineering and Technology of Baoding, Baoding, Hebei 071000, China
4. Technical Engineering Research Institute of China Petroleum North China Oil Field, Cangzhou, Hebei 061000, China
全文: PDF (723 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 针对传统近红外点对点探头传感器测量存在盲区、数据精度低等问题,提出并设计了一种基于近红外面源传感器的气液两相流相含率测量装置,并对其进行研究。该装置有效减小了近红外光的折射与反射,提高了测量的精确度。通过CFD流体仿真软件模拟了管道内流体的流动状态,并对该装置的结构进行了仿真及优化。在单相流实验的基础上进行气液两相流动态实验,得到了4路近红外信号与相含率的关系,建立了相含率测量模型,数据导入修正模型分析得到的相含率测量相对误差在±3.5%以内。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
方立德
王少冲
王配配
王松
王东星
郑庆龙
李小亭
关键词 计量学气液两相流近红外面源传感器相含率流量测量    
Abstract:Aiming at the problems of traditional near-infrared point-to-point probe sensor measurement blindness and low data accuracy, a gas-liquid two-phase flow phase content measurement device based on near-infrared surface source sensor was proposed and designed. The device effectively reduced the refraction and reflection of near-infrared light and improved the accuracy of the measurement. The flow state of the fluid in the pipeline was simulated by CFD fluid simulation software, and the structure of the device was simulated and optimized. Based on the single-phase flow experiment, the dynamic experiment of gas-liquid two-phase flow was carried out, and the relationship between the four-way near-infrared signal and the phase-containing ratio was obtained. The phase-containment rate measurement model was established, and the phase-inclusive rate measurement was obtained by data import correction model analysis. The relative error is within ±3.5%.
Key wordsmetrology    gas-liquid two-phase flow    near-infrared surface source sensor    phase volume fraction    flow measurement
收稿日期: 2018-07-04      发布日期: 2019-10-10
PACS:  TB937  
基金资助:基金项目:国家自然科学基金(61475041);国家重点研发计划子任务(2016YFF0203103-3,2017YFC0805703);河北省自然科学基金 (E2017201142);河北大学研究生创新资助项目(hbu2018ss81)
通讯作者: 李小亭(1957-), 女,河北保定人, 河北大学教授, 博士生导师,主要从事测试计量理论及应用方面的研究。Email: lxt@hbu.edu.cn     E-mail: lxt080@126.com
作者简介: 方立德(1974-), 吉林德惠人, 河北大学教授, 研究生导师, 主要从事热工参数(温度、压力、流量)的计量检测与控制、多相流检测技术、供热计量技术方面的研究。Email: fanglide@sina.com
引用本文:   
方立德,王少冲,王配配,王松,王东星,郑庆龙,李小亭. 基于近红外面源传感器的气液两相流相含率测量[J]. 计量学报, 2019, 40(6): 1043-1049.
FANG Li-de,WANG Shao-chong,WANG Pei-pei,WANG Song,WANG Dong-xing,ZHENG Qing-long,LI Xiao-ting. Phase Volume Fraction Measurement of Gas-liquid Two-phase Flow Based on Near-infrared Surface Source Sensor. Acta Metrologica Sinica, 2019, 40(6): 1043-1049.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2019.06.17     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2019/V40/I6/1043
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn