Abstract:The short pulse E-field standard facility based on monocone was developed. The inter-laboratory comparison between Northwest Institute of Nuclear Technology, All-Russian Research Institute for Optophysical Measurements and Department of Engineering Physics of Tsinghua University were held in China and Russia which aim to verify the veracity of the standard facility. The equivalent area of transfer standard (D-dot) was calibrated in three standard facilities. Test results show that the waveforms of the D-dot sensor measured in the three laboratories are consistent with the excitation waveforms at the given position of α=70°, r=0.6m in monocone, and the difference of the effective area of the sensor is less than 2%. The comparison results verify that the monocone generates short electromagnetic pulse standard field and can be used for antenna time-domain calibration.
[1]IEEE 1309-2013. IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9kHz to 40GHz [S]. 2013.
[2]Sakharov K Y, Mikheev O V, Turkin V A. National Standard of Russian Federation for reproduction and transmission of unit sizes of pulse electric and magnetic intensities in ultrawide band range [C]// The 18th High-Power Electromagnetics Conference, 2012.
[3]Joo-Gwang Lee, Jin-Seob Kang, Jeong-Hwan Kim. Time domain antenna range at KRISS [C]// 2008 Conference on Precision Electromagnetic Measurements Digest, 2008.
[4]Lawton R A, Ondrejka A U. Antenna and the Associated Time Domain Range for the Measurement of Impulse Field. U. S [R]. National Bureau of Standards Technical Note 1008, 1978.
[5]Yan Y J, Jiang T Y, Liu X L. Study of the time-domain electromagnetic pulse standard field generation setup and its application [J]. Review of secientific instruments, 2018, 89(7): 70-73.
[6]Yan Y J, Jiang T Y, Liu X L. E-field generation setup for UWB-SP sensor calibration [C]// APEMC, 2012.
[7]Jiang T Y, Liu X L, Yan Y J, et al. Theoretical and Experimental Study of Feed for the Monocone [C]// APEMC, 2012.
[8]Yang C, Meng C, Li P H, et al. Electromagnetic field standard device-monoconical TEM cell [J]. High Voltage Engineering, 2016, 42(5): 665-669.
[9]陈锦, 刘小龙, 燕有杰, 等. 小型短电磁脉冲传感器 [J]. 强激光与粒子束, 2012, 24(12): 2797-2801.
Chen J, Liu X L, Yan Y J,et al. Compact short electromagnetic pulse sensor[J]. High Power Laser and Particle Beams, 2012, 24(12):2797-2801.