Abstract:A method of analyzing the influence of the position deviation of the reading head to suppress the angular deviation is proposed based on multi-reading heads of equal average system. Theoretical analysis and simulation method of the angular deviation introduced by the non- ideal position of reading head are introduced. The harmonic error is separated and the decay rate of error amplitude is obtained. The method is applied to error analysis of the encoder, and the result shows that±0.09″ angular deviation can be introduced by 0.5° position deviation of reading head.
乔丹,薛梓,黄垚,叶树亮. 等分多读数头位置偏差对测角误差的影响研究[J]. 计量学报, 2017, 38(6): 676-680.
QIAO Dan,XUE Zi,HUANG Yao,YE Shu-liang. Study on Influence of Position Deviation of Multi-reading Heads ofEqual Average on Angular Measurement. Acta Metrologica Sinica, 2017, 38(6): 676-680.
[1]付永启. 新型圆光栅多头读数系统的研究[J]. 计量技术, 1996,(5):11-14.
[2]朱应时, 杨进堂. 圆光栅的高精度高质量莫尔条纹信号的研究[J]. 计量学报, 1995, 16(4):280-285.
[3]邹自强.论圆光栅多头读数系统[J]. 光学精密工程, 1983,(2):39-48.
[4]Masuda T, Kajitani M. An automatic calibration system for angular encoders[J]. Journal of the Japan Society for Precision Engineering, 1989, 11(2):95-100.
[5]Watanabe T. Compact self-calibratable rotary encoder[C]//20th IMEKO world congress 2012, Busan, Korea, 2012.
[6]黄龙,潘年,马文礼,等.拼接式编码器测角误差分析及试验[J]. 中国光学, 2015,8(3):464-470.
[7]Huang Y, Xue Z, Lin H, et al. Development of portable and real-time self-calibration angle encoder[C]//Seventh International Symposium on Precision Mechanical Measurements, Xiamen, China, 2015.
[8]Wang Y, Xue Z, Huang Y, et al. Study on self-calibration angle encoder using simulation method[C]// Seventh International Symposium on Precision Mechanical Measurements. Xiamen, China, 2015.
[9]娄云鸽,严隽藩,陈伟伟.提高测角精度的双读数头转台设计[J]. 机械制造, 2015, 53(1):17-19.
[10]张天恒,王培懿,武亮,等.时栅转台自动标定系统的研究[J]. 计量学报, 2016, 37(1): 6-9.
[11]陈锡侯,苟李,官云丽,等.基于单个读数头的角位移传感器自标定方法[J]. 传感技术学报, 2014,27(8):1049-1053.
[12]马国庆.高精度伺服转台关键技术研究[D]. 哈尔滨:哈尔滨工业大学, 2010.
[13]折文集, 高立民, 杨永清,等.激光跟踪仪测角误差标定及补偿[J].仪器仪表学报. 2015,36(z1):52-56.
[14]苏东风,续志军,贾继强,等.提高圆光栅测角系统精度的读数头设计[J]. 电子测量与仪器学报,2013,27(7):653-657.
[15]张善钟.高精密圆分度测量装置中多读数头结构的消除误差原理[J]. 工具技术, 1982,(6):42-46.
[16]Huang Y, Xue Z, Qiao D, et al. Study on the metrological performance of self-calibration angle encoder[C]// Eighth International Symposium on Advanced Optical Manufacturing and Testing Technology. Suzhou, China, 2016.