Abstract:In order to solve the measurement error caused by the detection time delay of the pressure switch, an automatic calibration method is designed based on the comparison of the switching error of the pressure switch. According to the research on the mechanism of the automatic calibration of the pressure switch, a comparative model of the cycle approach is constructed, and the function relation between the switching error of the pressure switch and the rate of pressure change is determined. Using model scheme, the automatic calibration system is built. The closed loop feedback to adjust the rate of pressure change in real time is used, the switching value is obtained. The influence of pressure change rate and delay time is reduced in the calibration process by the automatic calibration method, and the experimental results show that the measurement accuracy is improved by 50%.
[1]刘豪.压力开关的特点及其类型[J].企业导报,2011,(6):296.
[2]张振兴,刘君.压力开关自动检测系统研究[D].西安:西安理工大学,2009.
[3]朱斌强,杨世锡.工程机械中压力开关可靠性试验研究[D].杭州:浙江大学,2011.
[4]张忠立,周毅冰,丁思丝,等.一种针对压力开关的新型高效的校准方法[J].工业计量,2013,23(6):10-13.
[5]刘俭岐.介绍一种压力开关设定点误差超差后的调整方法[J].计量技术,2012,(9):54-55.
[6]蓝林海,钟勇.3KY-1压力开关的可靠性设计探讨[J].机电元件,2000,20(4):12-16.
[7]JJG544-2011 压力开关控制检定规程[S]. 2011.
[8]张剑平.压力开关智能化动态测试系统设计[J].传感器世界,2004,10(2):35-37.
[9]阮祥发,蒋飞.压力开关自动调整测控系统的研究[J].机械工程与自动化, 2005,(5):20-22.
[10]Wu A M. Automatic Calibration System of Pressure-measuring Instruments and Intelligent Management System of Metrological Information[C]// Proceeding of IPSV′ 2003 International Symposium on Pressure and Vacuum, Beijing, 2003.
[11]李燕华,孙俊峰.基于活塞式压力计和数字压力计的微小压力测量新方法[J].计量学报,2012,33(6):528-531.