Abstract:Based on the validation of field uniformity, fluctuation of root-mean-square (RMS) delay simulated in reverberation chamber is also investigated, by considering the disturbance introduced by mechanical stirring and positions of receiving antenna. The field uniformity of reverberation chamber is proved to be better than 2.5dB, and the range of RMS delay is also quantitatively evaluated. The differences between the field uniformity and the fluctuation are analyzed for indicating the different roles that they played in some applications.
郭晓涛,何昭,黄见明,周鑫,王少华. 电磁混响室内的场均匀性与均方根时延展宽波动性研究[J]. 计量学报, 2017, 38(1): 102-105.
GUO Xiao-tao,HE Zhao,HUANG Jian-ming,ZHOU Xin,WANG Shao-hua. Research on Uniformity of Field and Fluctuation of RMS Delay in Reverberation Chamber. Acta Metrologica Sinica, 2017, 38(1): 102-105.
[1]Corona P, Ladbury J, Latmiral G. Reverberation-chamber research-then and now: a review of early work and comparison with current understanding[J]. Electromagnetic Compatibility IEEE Transactions on, 2002, 44(1):87-94.
[2]Piette M, Tsigros C. IEC 61000-4-21 testing : Selective source-mode tuning with two orthogonal antennas scanning system[C]// Electromagnetic Compatibility-EMC Europe, 2008 International Symposium on IEEE, 2008: 1-6.
[3]IEC. IEC 61726—1999,Cable assemblies, cables, connectors and passive microwave components-screening attenuation measurement by the reverberation chamber method[S].1999.
[4]Rudander J H, Ikram-e-Khuda, Kildal P S, et al. Measurements of RFID Tag Sensitivity in Reverberation Chamber[J]. Antennas & Wireless Propagation Letters IEEE, 2011, 10:1345-1348.
[5]Chen X, Kildal P S, Hussain A, et al. Overview of state-of-the-art OTA measurements of wireless devices in reverberation chamber[C]// Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on IEEE, 2014: 301-306.
[6]Patane C L, Skarbratt A, Rehammar R, et al. On the use of reverberation chambers for assessment of MIMO OTA performance of wireless devices[C]// Antennas and Propagation (EuCAP), 2013 7th European Conference on IEEE, 2013: 101-105.
[7]Ladbury J, Koepke G, Camel D. Evaluation of the NASA Langley Research Center Mode-Stirred Chamber Facility[R]. Nist Technical Note 1508, 1999.
[8]Guo X, He Z, Zhang Y, et al. Theoretical uncertainty of RMS delay spread simulated by reverberation chamber[C]// International Conference on Electronic Measurement & Instruments (ICEMI), 2015.
[9]Chen X, Kildal P S. Theoretical derivation and measurements of the relationship between coherence bandwidth and RMS delay spread in reverberation chamber[C]// Antennas and Propagation, 2009. EuCAP 2009. 3rd European Conference on IEEE, Berlin,2009: 2687-2690.