2025年04月06日 星期日 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2024, Vol. 45 Issue (3): 425-432    DOI: 10.3969/j.issn.1000-1158.2024.03.17
  几何量计量 本期目录 | 过刊浏览 | 高级检索 |
基于PSD的分离式长导轨直线度测量方法研究
金挺1,2,朱进1,2,陈挺1,2,郭斌1,2,沈斌3,孔明4,程银宝4,王瑛辉1,2
1. 浙江省计量科学研究院,浙江杭州310018
2. 浙江省数字精密测量技术研究重点实验室,浙江杭州310018
3.杭州光尺科技有限公司,浙江杭州310018
4. 中国计量大学,浙江杭州310018
Research on PSD-based Straightness Measurement Method of Separated Long Guide Rail
JIN Ting1,2,ZHU Jin1,2,CHEN Ting1,2,GUO Bin1,2,SHEN Bin3,KONG Ming4,CHENG Yinbao4,WANG Yinghui1,2
1. Zhejiang Institute of Metrology,Hangzhou,Zhejiang 310018,China
2.Key Laboratory of  Digital Precision Measurement Technology of Zhejiang Province, Hangzhou, Zhejiang 310018, China
3. Hangzhou Optical  Ruler Technology Co., Ltd., Hangzhou, Zhejiang 310018, China
4.China Jiliang University, Hangzhou, Zhejiang 310018, China
全文: PDF (662 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 利用分段拼接测量方法能够将PSD激光准直测量系统测量范围扩大,相较于传统长导轨直线度测量方法,该方法可同时适用于连续型导轨和分离式超长导轨的直线度测量。首先,在(-5~+5)mm 测量范围内,通过激光干涉仪分别测得激光准直测量系统的接收靶在水平和竖直方向上的位移,误差均优于±(1μm+1%H)。然后,在40m范围内与激光准直测量系统的直线度测量精度进行对比,二者水平方向直线度误差相差0.06mm,竖直方向直线度误差相差0.13mm。最后,在70m分离式超长导轨上,测得水平方向直线度为0.50m,竖直方向直线度为05.3mm。该方法可迅速定位和调整直线度误差极值点位置,能够较为有效地解决分离式超长导轨的直线度装配调试问题
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
金挺
朱进
陈挺
郭斌
沈斌
孔明
程银宝
王瑛辉
关键词 几何量计量超长导轨 直线度 拼接方法 最小二乘    
Abstract:The measuring range of the PSD-laser collimation measuring system can be expanded by using the piecewise splicing measurement method.Compared with the traditional method of measuring the straightness of long guide rails, the mentioned method can be used to measure the straightness of both continuous guide rails and separated superlong guide rails. Firstly, in the measuring range of (-5~+5)mm, the horizontal and vertical displacements of the receiving target of the laser collimation measurement system are respectively measured by the laser interferometer, and the errors are better than ±(1μm+1%H). Then, the straightness measurement accuracy is compared with that of the laser collimation measurement system in the range of 40m. The deviation of straightness in the horizontal direction is 0.06mm, and the deviation of straightness in the vertical direction is 0.13mm. Finally, the horizontal straightness is 0.50mm and the vertical straightness is 0.53mm on the 70m separated ultralong guide rail. The method can quickly locate and adjust the position of the extreme point of straightness error, and can effectively solve the problem of straightness assembly and debugging of separated ultralong guide rails.
Key wordsgeometric metrology    long guide rail    straightness    stitching method    least square
收稿日期: 2023-09-18      发布日期: 2024-03-25
PACS:  TB921  
基金资助:浙江省科技厅“尖兵”“领雁”研发攻关计划 (2022C01139)
通讯作者: 王瑛辉(1980-),河北张家口人,浙江省计量科学研究院高级工程师,主要从事几何量计量方面的研究。Email: 526276612@qq.com     E-mail: 526276612@qq.com
作者简介: 金挺(1973-),浙江东阳人,浙江省计量科学研究院高级工程师,主要从事几何量计量方法和装置方面的研究。Email: 2246771442@qq.com
引用本文:   
金挺,朱进,陈挺,郭斌,沈斌,孔明,程银宝,王瑛辉. 基于PSD的分离式长导轨直线度测量方法研究[J]. 计量学报, 2024, 45(3): 425-432.
JIN Ting,ZHU Jin,CHEN Ting,GUO Bin,SHEN Bin,KONG Ming,CHENG Yinbao,WANG Yinghui. Research on PSD-based Straightness Measurement Method of Separated Long Guide Rail. Acta Metrologica Sinica, 2024, 45(3): 425-432.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2024.03.17     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2024/V45/I3/425