6 种典型流场中超声流量计校准系数随企业污染源烟气排放量变化研究

方昱雯,张亮,赵不贿,王池

计量学报 ›› 2022, Vol. 43 ›› Issue (6) : 753-759.

PDF(4195 KB)
PDF(4195 KB)
计量学报 ›› 2022, Vol. 43 ›› Issue (6) : 753-759. DOI: 10.3969/j.issn.1000-1158.2022.06.08
流量计量

6 种典型流场中超声流量计校准系数随企业污染源烟气排放量变化研究

  • 方昱雯1,2,3,张亮2,3,赵不贿1,王池2,3
作者信息 +

Research on Change of Calibration Coefficient of Ultrasonic Flowmeter with the Amount of Enterprise Pollution Source Flue Gas in Six Typical Flow Fields

  • FANG Yu-wen1,2,3,ZHANG Liang2,3,ZHAO Bu-hui1,WANG Chi2,3
Author information +
文章历史 +

摘要

采用计算流体力学方法,对6种典型流场中超声流量计校准系数随企业污染源烟气不同流速变化的规律进行研究。分析不同负荷下超声流量计校准系数相对标准偏差在不同声道角度、管道直径、声道布置形式、上游直管段长度、管道形式时的变化规律。通过国家烟道流量计量标准装置进行实验验证,验证结果表明:不同负荷下校准系数相对标准偏差均未超过1%,且可以通过单负荷校准实现对烟道超声流量计的校准。

Abstract

Computational fluid dynamics is used to study the variation of calibration coefficient of ultrasonic flowmeter with different loads of the enterprise in six typical flow fields. The variation of relative standard deviation of calibration coefficient of ultrasonic flowmeter under different loads is analyzed under different path angle, pipe diameter, path layout, length of upstream straight pipe and pipe form. Through the experimental verification of the national stack flowrate standard facility, the results show that the relative standard deviation of calibration coefficient under different loads is less than 1%, and the stack ultrasonic flowmeter can be calibrated by single load calibration.

关键词

计量学 / 超声流量计 / 流速变化 / 校准系数 / 烟道流量 / 相对标准偏差

Key words

metrology;ultrasonic flowmeter;different flow velocity;calibration coefficient / stack flowrate / relative standard deviation

引用本文

导出引用
方昱雯,张亮,赵不贿,王池. 6 种典型流场中超声流量计校准系数随企业污染源烟气排放量变化研究[J]. 计量学报. 2022, 43(6): 753-759 https://doi.org/10.3969/j.issn.1000-1158.2022.06.08
FANG Yu-wen,ZHANG Liang,ZHAO Bu-hui,WANG Chi. Research on Change of Calibration Coefficient of Ultrasonic Flowmeter with the Amount of Enterprise Pollution Source Flue Gas in Six Typical Flow Fields[J]. Acta Metrologica Sinica. 2022, 43(6): 753-759 https://doi.org/10.3969/j.issn.1000-1158.2022.06.08
中图分类号: TB937   

参考文献

[1]樊洁云. 烟气超声流量计非实流校准方法研究[D]. 保定: 河北大学, 2020.
[2]邓千封, 张亮, 方立德, 等. 烟道流量计量标准装置[J]. 计量学报, 2020, 41(5): 567-572.
Deng Q F, Zhang L, Fang L D, et al. Stack Flowrate Standard Facility[J].  Acta Metrologica Sinica,  2020, 41(5): 567-572.
[3]杨阳, 张亮, 张洪军, 等. 烟道截面面积校准装置模型研究及不确定度评定[J]. 计量学报, 2020, 41(11): 1364-1369.
Yang Y, Zhang L, Zhang H J, et al. Study on the Stack Cross Section Area Calibration Facility and its Uncertainty Evaluation[J].  Acta Metrologica Sinica,  2020, 41(11): 1364-1369.
[4]胡鹤鸣, 王池, 张金涛. 城市区域碳排放测量反演研究国际进展[J]. 计量学报, 2017, 38(1): 7-12.
Hu H M, Wang C, Zhang J T. International Research Overview of Inversion Approach of Carbon Emission Measurement in Urban Area[J].  Acta Metrologica Sinica,  2017, 38(1): 7-12.
[5]龚颖, 王洪涛. 发电企业温室气体核算方法与报告指南对比研究[J]. 化学工程与装备, 2015(3): 234-236.
Gong Y, Wang H T. Comparative Study on Greenhouse Gas Accounting Methods and Reporting Guidelines for Power Generation Companies[J].  Chemical Engineering & Equipment,  2015 (3): 234-236.
[6]Quick J C. Carbon Dioxide Emission tallies for 210 U. S. Coal-fired Power Plants: A Comparision of Two Accounting Methods[J].  Journal of the Air & Waste Management Association,  2014, 64(1): 73-79.
[7]HJ 75-2017固定污染源烟气(SO2、NOx、颗粒物)排放连续监测技术规范[S]. 2017.
[8]郭淑梅, 单新宇, 李自喜, 等. 超声波流量计性能影响因素及改进措施[J]. 计量技术, 2016(6): 76-79.
[9]Palau C V, de Bomfim G V, de Azevedo B M, et al. Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters[J].  Scientia Agricola,  2018, 77(4): e20180208.
[10]赵伟国, 卜勤超,姚海滨, 等. 基于双声道的低压超声气体流量计数据融合方法[J]. 计量学报, 2021, 42(7): 873-878.
Zhao W G, Bu Q C,Yao H B, et al. A Data Fusion Method of Double-channel Ultrasonic Flowmeter Application in Low Pressure Gas[J].  Acta Metrology Sinica,  2021, 42(7): 873-878.
[10]穆立彬, 徐科军, 刘博, 等. 基于可变阈值和过零检测的四声道气体超声波流量变送器[J]. 计量学报, 2019, 40(2): 266-271.
Mu L B, Xu K J, Liu B, et al. Development of Four-channel Ultrasonic Gas Flow Transmitter Based on Variable Threshold and Zero-crossing Detection[J].  Acta Metrology Sinica,  2019, 40(2): 266-271.
[11]张硕. 气体超声流量计在不同压力状态下的计量特性分析[J]. 中国计量, 2020(3): 76-79.
[12]Walsh J T. A report of acoustic transit time accuracy field work performed in North America[C]//5th International Conference on Hydraulic Efficiency Measurements. Switzerland, Lucerne, 2004.
[13]Johnson A N, Harman E, Boyd J T. Design and Capabilities of NISTs Scale-Model Smokestack Simulator(SMSS)[C]//9th SFFM, Arlington, Virginia, 2015.
[14]Kurnadi D, Trisnobudi A. A multi-path ultrasonic transit time flow meter using a tomography method for gas flow velocity profile measurement[J].  Particle and Particle Systems Characterization,  2006, 23(3-4): 330-338.
[15]郑丹丹, 张朋勇, 孙立军, 等. 单弯管下游超声流量计的安装和测量性能研究[J]. 仪器仪表学报, 2010, 31(7): 1601-1607.
Zheng D D, Zhang P Y, Sun L J, et al. Study on Installation and Performance Measurement of Ultrasonic Flowmeter at Downstream of Single Bend Pipe[J].  Chinese Journal of Scientific Instrument,  2010, 31(7): 1601-1607.
[16]杨卓群, 胡鹤鸣, 杨卓. 矩形明渠超声流量计积分方法检验软件[J]. 计量技术, 2019, (4): 6-11.
[17]Mattingly G E, Yeh T T. NISTs Industry-Government Consortium Research Program on Flowmeter Installation Effects: Report of Results for the Research Period Nov[R]. NISTIR 4310, 1989.

基金

国家重点研发计划(2017YFF0205301)

PDF(4195 KB)

Accesses

Citation

Detail

段落导航
相关文章

/