2025年04月15日 星期二 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2021, Vol. 42 Issue (5): 650-657    DOI: 10.3969/j.issn.1000-1158.2021.05.17
  电离辐射、标准物质与生物计量 本期目录 | 过刊浏览 | 高级检索 |
基于不确定度评价对稻米中镉元素分析标准物质高精度定值方法的比较
周明慧,伍燕湘,陈曦,王松雪
国家粮食和物资储备局科学研究院,北京 100037
Comparison of Methods for Cadmium Analysis in the Rice Matrix Certified Standard Reference Material Based on Uncertainty Evaluation
ZHOU Ming-hui,WU Yan-xiang,CHEN Xi,WANG Song-xue
Academy of National Food and Strategic Reserves Administration, Beijing 100037, China
全文: PDF (1447 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 通过对稻米中镉含量测定的3种典型方法(石墨炉原子吸收光谱法(GFAAS)、电感耦合等离子体质谱法(ICP-MS)和同位素稀释电感耦合等离子体质谱法(ID-ICP-MS))测量不确定度分量来源、类型、贡献进行系统分析比较,为稻米镉分析标准物质高精度定值方法的选择和定值的过程控制提供依据。研究结果显示,GFAAS、ICP-MS和ID-ICP-MS测试稻米中镉结果分别为0.478±0.028,0.488±0.022,0.485±0.014mg/kg(k=2),ID-ICP-MS的测量不确定度显著小于其他2种方法,结果精密度更高,同时是可直接通过天平称重和同位素丰度比的测量溯源至SI单位的基准方法,是稻米中镉分析标准物质定值的理想方法;GFAAS和ICP-MS不确定度较ID-ICP-MS大,但相对扩展不确定度也仅为5.7%和4.4%,满足于多种不同原理方法定值研究。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
周明慧
伍燕湘
陈曦
王松雪
关键词 计量学稻米标准物质定值方法不确定度评价    
Abstract:Through systematic analysis and evaluation of source, type and contribution of uncertainty for three classical methods including graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma mass spectrometry (ICP-MS) and isotope dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS), it provides basic data for the selection of the best method, and contributed to the process control of the assignment value in the development of cadmium in rice matrix certified standard reference materials. The detected value are 0.478±0.028, 0.488±0.022, 0.485±0.014 mg/kg(k=2) for the GFAAS, ICP-MS and ID-ICP-MS respectively. The ID-ICP-MS proved to be the most reliable method and had the smallest uncertainty for the determination of cadmium in rice, at the same time, the ID-MS method is a benchmark method that can directly trace to the SI unit through the balance weighing and isotope abundance ratio. Therefore, it is an ideal method for determining the cadmium in the rice matrix standard reference materials. Although the uncertainties of GFAAS and the ICP-MS are larger than that of the ID-ICP-MS, the relative expanded uncertainty are only 5.7% and 4.4%, which also could be applied to the value assignment of inter-laboratory studies with different methods.
Key wordsmetrology    rice    cadmium    reference material    value assignment    uncertainty evaluation
收稿日期: 2019-08-30      发布日期: 2021-05-24
PACS:  TB99  
基金资助:国家重点研发计划(2017YFC1601300)
通讯作者: 王松雪(1977-),安徽阜阳人,国家粮食和物资储备局科学研究院研究员,主要从事粮油污染物监测预警技术方面的研究。Email:wsx@chinagrain.org     E-mail: wsx@chinagrain.org
作者简介: 周明慧(1984-),黑龙江拜泉人,国家粮食和物资储备局科学研究院副研究员,研究方向为粮油中无机元素分析、监测及质控技术。Email:zmh@chinagrain.org
引用本文:   
周明慧,伍燕湘,陈曦,王松雪. 基于不确定度评价对稻米中镉元素分析标准物质高精度定值方法的比较[J]. 计量学报, 2021, 42(5): 650-657.
ZHOU Ming-hui,WU Yan-xiang,CHEN Xi,WANG Song-xue. Comparison of Methods for Cadmium Analysis in the Rice Matrix Certified Standard Reference Material Based on Uncertainty Evaluation. Acta Metrologica Sinica, 2021, 42(5): 650-657.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2021.05.17     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2021/V42/I5/650
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn