Real-time Load Pull Measurement Technique Based Vector Error Correction Method
WANG Yi-bang1,LUAN Peng1,HUO Ye1,WU Ai-hua1,LIANG Fa-guo1,DU Jing2
1. The 13th Research Institute of China Electronics Technology Group Corporation, Shijiazhuang, Hebei 050051, China
2. Shijiazhuang Division of Army Infantry College of PLA, Shijiazhuang, Hebei 050051, China
Abstract:A novel load pull measurement technique based vector error correction method is developed. The technique includes the 8-term vector error calibration on the vector network analyzer and one-tier absolute power calibration for one receiver within the vector network analyzer, which could obtain the input/load reflection coefficient, input/output power and power gain for the device under test at one time. Then the measurement system is set up based the proposed method. Compared with the commercial Focus load pull system, the test result shows they have promising results, which demonstrates the accuracy of the proposed method.
[1]Cusack J M, Perlow S M, Perlman B S. Automatic load contour mapping for microwave power transistors[J]. IEEE Trans Microwave Theory Tech, 1974, 22(12): 1146-1152.
[2]Takayama Y. A new load-pull characterization method for microwave power transistors[C]//Proc IEEE MTT-S International Symposium. Cherry Hill, 1976: 218-220.
[3]Stanchff R B, Poulm D D. Harmonic load pull[C]//IEEE MTT-S International Microwave Symposium Digest, Orlando, 1979: 185-187.
[4]唐宗熙, 李恩. 微波功率固态放大器负载牵引特性的自动测试[J]. 计量学报, 2004, 25(4): 362-365.
Tang Z X, Li E. Automatic Measurement of Load-pull Property of Power Solid-state Amplifiers at Microwave Frequency[J]. Acta Metrologica Sinica. 2004, 25(4): 362-365.
[5]Bava G P, Pisani U, Pozzolo V. Active load techniques for load-pull characterization at microwave frequencies[J]. Electron Lett, 1982, 18(4): 178-180.
[6]Tucker R S, Bradley P D. Computer-aided error correction of large-signal load-pull measurements[J]. IEEE Tran Microw Wave Theory Techn, 1984, 32 (3): 296-301.
[7]Teppati V, Ferrero A, Pisani U. Recent Advances in Real-Time Load-Pull Systems[J]. IEEE Trans Instrum Meas, 2008, 57(11): 2640-2646.
[8]Ferrero A, Teppati V, Carullo A. Accuracy Evaluaiton of On-Wafer Load-Pull Measurements[J]. IEEE Trans Microw Wave Theory Techn, 2001, 49(1): 39-43.
[9]Focus Microwave Inc. [Online]. Aug 2011.Available: http://www. focus-microwaves. com
[10] Maury Microwave Corporation. [Online]. Aug 2011.Available: http://www. maurymw. com
[11]High Frequency Engineering. [Online]. Aug 2011.Available: http://www. hfemicro. com.
[12]Teppati V, Bolognesi C R. Evaluation and Reduction of Calibration Residual Uncertainty in Load-Pull Measurements at Millimeter-Wave Frequencies[J]. IEEE Trans Instrum Meas, 2008, 61(3): 120-133.
[13] Bonino S, Teppati V, Ferrero A. Further improvements in Real-time load-pull measurements accuracy[J]. IEEE Microw wire comp Lett, 2010, 20(2): 121-123.
[14]Marks R B. Formulations of the basic vector network analyzer error model including switch terms[C]//50th ARFTG Conference. Portland, 1997, 32: 121-126.
[15]王一帮, 栾鹏, 吴爱华, 等. 基于Multi-TRL算法的传输线特征阻抗定标[J]. 计量学报, 2017, 38(1): 1-5.
Wang Y B, Luan P, Wu A H, et al. An Accurate Determination Method of Characteristic Impedance of Transmission Line Based on Multi-TRL Algorithms[J]. Acta Metrologica Sinica, 2017, 38(1): 1-5.
[16]栾鹏, 王一帮, 吴爱华, 等. 共面波导传输线电容准确测量及不确定度分析[J]. 计量学报, 2018, 39(2): 272-275.
Luan P, Wang Y B, Wu A H, et al. Coplanar Waveguide Transmission Line Capacitance Measurement and Uncertainty Analysis[J]. Acta Metrologica Sinica, 2018, 39(2): 272-275.