2025年05月30日 星期五 首页   |    期刊介绍   |    编 委 会   |    投稿指南   |    期刊订阅   |    统合信息   |    联系我们
计量学报  2021, Vol. 42 Issue (10): 1343-1348    DOI: 10.3969/j.issn.1000-1158.2021.10.13
  电磁学计量 本期目录 | 过刊浏览 | 高级检索 |
变压器工频短路电流测量技术研究
梅国健1,5,李传生2,王家福2,赵叶铭3,董平4,邵海明2,姚燕1
1.中国计量大学, 浙江 杭州 310018
2.中国计量科学研究院, 北京100029
3.北京信息科技大学, 北京100192
4.山西省计量科学研究院, 山西 太原 030021
5. 浙江省计量科学研究院, 浙江 杭州 310018
Research on Measurement Technology of Power Frequency Short-circuit Current of Transformer
MEI Guo-jian1,5,LI Chuan-sheng2,WANG Jia-fu2,ZHAO Ye-ming3,DONG Ping4,SHAO Hai-ming2,YAO Yan1
1. China Jiliang University, Hangzhou, Zhejiang 310018, China
2. National Institute of Metrology, Beijing 100029, China
3. Beijing University of Science and Technology Information, Beijing 100192, China
4. Shanxi Institute of Metrology, Taiyuan, Shanxi 030021, China
5. Zhejiang Province Institution of Metrology, Hangzhou, Zhejiang 310018, China
全文: PDF (2869 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 针对变压器工频短路电流测量需求,研究了外积分式罗氏线圈技术和光纤电流传感技术。建立了2种传感器的低频数学模型,基于MATLAB/Simulink仿真计算传感器对工频短路电流的响应特性,结果表明:罗氏线圈对工频短路电流的测量精度受其下截止频率影响,下截止频率越低,测量精度越高;光纤电流传感器理论上可以精确复现工频短路电流。采用多种电流传感器进行变压器工频短路电流现场对比测试,结果表明:电流比较仪、光纤电流传感器及下截止频率为0.02Hz的罗氏线圈测得的电流波形吻合较好,而下截止频率为0.2Hz的罗氏线圈测量结果出现了明显的偏移,且无法归零,与仿真分析结论基本一致。对于外积分式罗氏线圈,为保证高精度测量,建议下截止频率应低于0.1Hz;光纤电流传感器具有极好的直流及低频响应特性,是工频短路电流高精度测量的理想方案。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
梅国健
李传生
王家福
赵叶铭
董平
邵海明
姚燕
关键词 计量学工频短路电流光纤电流传感器罗氏线圈    
Abstract:Aiming at the requirements of transformer power frequency short-circuit current measurement, the external integral Rogowski coil technology and fiber-optic current sensing technology are studied. The low-frequency mathematical models of the two sensors are established which based on MATLAB/Simulink to calculate the response characteristics of the sensor to the power-frequency short-circuit current. The results show that the measurement accuracy of the Rogowski coil for the power-frequency short-circuit current is affected by its lower cut-off frequency. If the cut-off frequency is lower, the measurement accuracy will be higher. The optical fiber current sensor can theoretically accurately reproduce the power frequency short-circuit current. Multiple current sensors are used for the field comparison test of the transformers power frequency short-circuit current. The results show that the current waveforms measured by the AC/DC current comparator, the fiber-optic current sensor, and the Rogowski coil with a lower cut-off frequency of 0.02Hz agree well, the measurement result of the lower cut-off frequency in Rogowski coil at 0.2Hz shows a significant deviation and could not be reset to zero, which is consistent with the simulation analysis conclusion. It is recommended that the lower cut-off frequency should be lower than 0.1Hz for the external integral Rogowski coil in order to ensure high-precision measurement; fiber-optic current sensor has excellent DC and low-frequency response characteristics, it is an ideal scheme for high-precision measurement of power frequency short-circuit current.
Key wordsmetrology    power frequency short-circuit current    fiber-optical current sensor    Rogowski coil
收稿日期: 2020-01-30      发布日期: 2021-10-18
PACS:  TB971  
基金资助:国家重点研发计划(2016YFF0201202, 2016YFF0102404)
通讯作者: 李传生(1984-),黑龙江鹤岗人,中国计量科学研究院副研究员,博士,主要从事光纤电流传感技术、宽带大电流计量技术方面的研究。Email: lichsh@nim.ac.cn      E-mail: lichsh@nim.ac.cn
作者简介: 梅国健(1993-),浙江兰溪人,中国计量大学硕士研究生,研究方向为电压互感器检测与图像处理。Email: mgj0212@qq.com
引用本文:   
梅国健,李传生,王家福,赵叶铭,董平,邵海明,姚燕. 变压器工频短路电流测量技术研究[J]. 计量学报, 2021, 42(10): 1343-1348.
MEI Guo-jian,LI Chuan-sheng,WANG Jia-fu,ZHAO Ye-ming,DONG Ping,SHAO Hai-ming,YAO Yan. Research on Measurement Technology of Power Frequency Short-circuit Current of Transformer. Acta Metrologica Sinica, 2021, 42(10): 1343-1348.
链接本文:  
http://jlxb.china-csm.org:81/Jwk_jlxb/CN/10.3969/j.issn.1000-1158.2021.10.13     或     http://jlxb.china-csm.org:81/Jwk_jlxb/CN/Y2021/V42/I10/1343
京ICP备:14006989号-1
版权所有 © 《计量学报》编辑部
地址:北三环东路18号(北京1413信箱)  邮编:100029 电话:(010)64271480
本系统由北京玛格泰克科技发展有限公司设计开发  技术支持:support@magtech.com.cn