摘要

基于一种交流电桥自动辅助平衡方法,中国计量科学研究院(NIM)研制了新一代二端对电容电桥装置。电桥采用固定比率的感应耦合比率臂电桥,通过复用比率,用单一电桥即实现了计算电容过渡和电容10:1传递;采用一种改进的靴带法实现电桥感应比率臂比率的精确校验。该装置用于电容单位的量值复现和标准电容器的高准度量值传递。利用新一代二端对电容电桥装置,可从计算电容装置复现1 pF电容值,并实现电容 1~100 pF的十进制量值传递,电容量值传递相对标准不确定度可达5×10-9(1592 Hz)。采用该电桥参加了10 pF和100 pF电容国际关键比对(CCEM.K4-2017),中国比对成绩优异,数据均非常接近关键比对参考值(KCRV),其中100 pF的结果最接近KCRV,与KCRV取得了很好的一致性,从而获得国际互认。

Abstract

An improved two terminal-pair coaxial AC bridge with auto source balance was constructed at NIM for high precision capacitance measurement. The errors introduced by auto source balance in the bridge are at negligible level. The bridge can disseminate the calculable capacitance to 1 pF, and transmit capacitance from 1 pF to 100 pF. An improved bootstrap method to calibrate the IVD ratios was adopted. A minimum standard uncertainty 5×10-9 was achieved at 1 592 Hz. The two terminal-pair capacitance bridge was applied to participate in the international key comparison of 10 pF and 100 pF capacitance standards, the comparison results showed that NIM's comparison results for 10 pF and 100 pF achieved a very good agreement with the KCRVs (key comparison recommended value), which obtained the international mutual recognition.

关键词

计量学;电容;交流电桥;感应分压器;交流阻抗;二端对 / 国际比对

Key words

metrology / capacitance / AC bridge / inductive voltage divider / AC impedance / two terminal pair / international comparison

引用本文

导出引用
杨雁,黄璐,王维,陆文俊,陆祖良. NIM新一代二端对电容电桥装置[J]. 计量学报. 2020, 41(3): 284-289 https://doi.org/10.3969/j.issn.1000-1158.2020.03.03
YANG Yan,HUANG Lu,WANG Wei,LU Wen-jun,LU Zu-liang. The New Two Terminal Pair Capacitance Bridge at NIM[J]. Acta Metrologica Sinica. 2020, 41(3): 284-289 https://doi.org/10.3969/j.issn.1000-1158.2020.03.03
中图分类号: TB971   

参考文献

[1]Huang L, Small G W, Lu Z L, et al. Model Tests of Electrical Compensation Method for the New Calculable Cross-Capacitor at NIM[J]. IEEE Trans Instrum Meas, 2013, 62(6): 1 789-1 794.
[2]张钟华. 用计算电容法绝对测定电学阻抗[J]. 物理, 1980, 9(1): 16-19.
Zhang Z H. Absolute determination of electrical imped-ance by the cross-capacitor method[J]. Physics, 1980,9(1): 16-19.
[3]Yang Y, Lu W, Zhao J, et al.An improved Two Terminal-Pair Capacitance Bridge at NIM[C]// Proc CPEM 2014. Rio de Janeiro, Brazil, 2014.
[4]陆祖良,黄璐,杨雁,等. 可动屏蔽型计算电容复现电容单位的方法研究[J]. 计量学报, 2014, 35(6): 521-527.
Lu Z L,Huang L,Yang Y,et al. Research for Reproducing SI Unit of Capacitance by the Calculable Capacitor with a Movable Guard Rod[J].Acta Metrologica Sinica, 2014, 35(6): 521-527.
[5]Yang Y, Lu W, Zhao J, et al. A Two Terminal-Pair Coaxial AC Bridge with Auto Source Balance at NIM[C]//Proc CPEM 2012. Washington, DC, USA, 2012.
[6]Zhao J, Yang Y, Lu Y, et al. An Improved Bootstrap Method for the Calibration of Inductive Voltage Dividers[C]// Proc CPEM 2012. Washington, DC, USA, 2012.
[7]Nakase T. Isolated-Section Inductive Divider and Its Self-Calibration[J]. IEEE Trans Instrum Meas, 1970,19(4): 312-317.
[8]Homan D, Zapf T. Two stage, guarded inductive voltage divider for use at 100 kHz[J]. ISA Trans, 1970, 9(2): 201-209.
[9]Thompson A M. AC bridge methods for the measurement of three-terminal admittance[J]. IEEE Trans Instrum Meas, 1964, 13(4): 189-197.
[10]张佑峰, 张钟华. 用增量法消除干扰因素的影响及用于校验感应式比例量具的参考增量法[J]. 计量学报, 1983, 4(3): 161-167.
Zhang Y F, Zhang Z H. Using an "Increment Method" to Eliminate the Stray Error Sources and a Derived "Reference Increment Method" for Calibrating the Inductive Ratio Devices[J]. Acta Metrologica Sinica, 1983, 4(3): 161-167.
[11]Hanke R. An improved straddling method with triaxial guards for the calibration of inductive voltage dividers at 1 592 Hz[J]. IEEE Trans Instrum Meas, 1989, 38(5): 974-978.
[12]Thompson A M. Precise Calibration of Ratio Transformers[J]. IEEE Trans Instrum Meas, 1983, 32(1): 47-50.
[13]Cutkosky R D, Shields J Q. The Precision Measurement of Transformer Ratios[J]. IRE Transcations on Instrumentation, 1960,1-9(2): 243-250.
[14]Shields J Q. Voltage Dependence of Precision Air Capacitors[J]. Journal of Res of the NBS, 1965, 69(4): 265-274.
[15]Gournay P, Rolland R, Chayramy R, et al. Comparison CCEM-K4. 2017 of 10 pF and 100 pF capacitance standards[J]. Metrologia, 2019, 56 (1A):01001.
第一作者:
杨雁(1978-),湖南岳阳人,男,中国计量科学研究院副研究员,博士,主要研究方向为阻抗标准、同轴电桥、精密电磁测量等。Email:yangyan@nim.ac.cn