Abstract:Y factor method is adopted to measure the efficiency of the adapters,and the effect of the method on the uncertainty of the noise power measurement is analyzed.A gas discharge noise source with waveguide connect is calibrated by the coaxial noise measurement system and the measurement uncertainty of the excess noise ratio is enlarged a little from 0.20 dB to 0.23 dB caused by using a waveguide-coaxial adapter.The results of the measurement show that the method is simple and efficient.
[1]Engen G F.An Evaluation of the “Back-to-Back” Method of Measuring Adaptor Efficiency[J].IEEE Transactions on Instrumentation and Measurement, 1970,19(1): 18-22.
[2]Lee Y S,Norm R.Improved Uncertainty for the Noise Source based on the Adapter Removal Methods[C]//56th ARFTG Conference Digest-Fall,Boulder,USA,2000.
[3]Randa J,Wiatr W,Billinger R L.Comparison of Adapter Characterization Methods[J]. IEEE Transactions on Microwave Theory and Techniques,1999,47(12):2613-2620.