基于恒温纯水置换称重法的容积测量方法与不确定度评定
张骏驰, 綦磊, 冯振辉, 芮小博, 孙立军, 杨子涵, 张宇
计量学报 ›› 2026, Vol. 47 ›› Issue (3) : 380-386.
PDF(990 KB)
PDF(990 KB)
基于恒温纯水置换称重法的容积测量方法与不确定度评定
Volumetric Measurement Using the Isothermal Pure Water Displacement Weighing Method and Evaluation of Its Measurement Uncertainty
基于恒温纯水置换称重法,设计并构建了正压平缓注水容积测量系统,验证了该系统在测量过程中的可靠性,并在此基础上制定了相应的测量方案与工艺流程。实验结果表明:1 000 ml标准容器及管路的容积测量值为1 008.06 ml,扩展不确定度U k=0.011 1%(k=2);200 ml标准容器及管路的测量值为215.77 ml,扩展不确定度Uk =0.019 7%(k=2)。所提出的方法为微流量校准系统的容积测量提供了稳定、可靠的解决方案,提高了流量计量设备的整体校准精度和测量一致性。
A low-velocity positive-pressure injection volume measurement system was designed and constructed based on the constant-temperature pure water displacement weighing approach. The reliability of the system during the measurement process was verified, and accordingly, a corresponding measurement scheme and process flow were established. Experimental results show that the measured volume of the 1 000 mL reference container and its associated piping is 1 008.06 mL, with an expanded uncertainty of 0.011 1% (k=2). For the 200 mL reference container and its piping, the measured volume is 215.77 mL, with an expanded uncertainty of 0.019 7%(k=2). The proposed method provides a stable and reliable solution for volume measurement in micro-flow calibration systems, thereby improving the overall calibration accuracy and measurement consistency of flow metering devices.
容积测量 / 恒温纯水置换称重法 / 微流量校准系统 / 正压注水 / 不确定度评定
volume measurement / constant-temperature pure water displacement weighing method / micro-flow calibration system / positive-pressure water injection / uncertainty evaluation
| [1] |
|
| [2] |
|
| [3] |
王筱庐,陈玉春,蒋宇翔.等 . 微小缝隙式层流流量计设计及测量特性研究[J].仪器仪表学报,2019,40(11):48-54.
|
| [4] |
魏万印,李得天,张涤新,等. 氙气质量流量校准装置[J]. 真空科学与技术学报, 2016, 36(9): 995-998.
|
| [5] |
黄震威,潘国兵,王文林,等. 恒温压动态法气体微小流量标准装置的研制[J]. 传感器与微系统, 2021, 40(2): 83-85, 88.
|
| [6] |
国家技术监督局. 卧式金属罐容积检定规程: JJG 266-1996 [S]. 北京: 中国标准出版社, 1996.
|
| [7] |
刘子勇,王金涛,郭立功,等 . 基于光电内测法的卧式油罐容量计量方法理论与试验研究[J]. 计量学报,2011,32(4) : 343 -345.
|
| [8] |
|
| [9] |
|
| [10] |
胡满红,王健,张跃,等. 基于声学原理的砝码体积测量方法研究[J]. 仪器仪表学报, 2012, 33(10): 2337-2342.
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
|
| [16] |
国家市场监督管理总局. 砝码:JJG 99-2022 [S]. 北京:中国质检出版社,2022.
|
| [17] |
IAPWS. Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam[R]. Lucerne, Switzerland: IAPWS Secretariat, 2007.
|
| [18] |
国家质量监督检验检疫总局. 测量不确定度评定与表示: JJF 1059.1-2012 [S]. 北京:中国质检出版社, 2012.
|
| [19] |
凌善康. 1990年国际温标[J]. 计量学报, 1990,11(4): 248-251.
|
| [20] |
全国钢标准化技术委员会(SAC/TC 183). 不锈钢 牌号及化学成分:GB/T 20878-2024 [S].中国标准出版社,2024.
|
/
| 〈 |
|
〉 |