基于静水拖曳法的超声测流装置时间差测量能力评价方法研究

沈佳明, 刘源, 张柯, 胡鹤鸣, 谢代梁

计量学报 ›› 2025, Vol. 46 ›› Issue (5) : 681-686.

PDF(919 KB)
PDF(919 KB)
计量学报 ›› 2025, Vol. 46 ›› Issue (5) : 681-686. DOI: 10.3969/j.issn.1000-1158.2025.05.09
流量计量

基于静水拖曳法的超声测流装置时间差测量能力评价方法研究

作者信息 +

Research on the Evaluation Method of Time Difference Measurement Capability of Ultrasonic Flow Measuring Devices Based on the Hydrostatic Towing Method

Author information +
文章历史 +

摘要

针对大口径超声测流装置时间差难以实现溯源的问题,提出了一套基于静水拖曳法的测量能力评价方案。从超声测流的原理出发,建立了超声传播时间差与流速量值之间的转换模型,并研制了基于静水拖曳法的实验测试装置和溯源路径,对转换模型进行了验证。通过6组传感器的实验测试结果,表明该测量能力评价方案具有可行性,由时间差测量引入的标准不确定度为0.26~0.49 ns。

Abstract

A measurement capability evaluation method based on the hydrostatic towing method was proposed to address the issue of difficulty in achieving traceability of the time difference of large-diameter ultrasonic flow measurement devices. Starting from the principle of ultrasonic flow measurement, a conversion model between ultrasonic transit time difference and flow velocity value was established. and an experimental testing device and traceability path based on the hydrostatic towing method were developed to verify the conversion model. The experimental test results of 6 sets of sensors indicated that the measurement capability evaluation method is feasible, and the standard uncertainty introduced by time difference measurement is 0.26~0.49 ns.

关键词

流量计量 / 超声测流装置 / 时间差 / 溯源 / 静水拖曳法 / 不确定度

Key words

flow measurement / ultrasonic flow measurement device / time difference / traceability / hydrostatic towing method / uncertainty

引用本文

导出引用
沈佳明, 刘源, 张柯, . 基于静水拖曳法的超声测流装置时间差测量能力评价方法研究[J]. 计量学报. 2025, 46(5): 681-686 https://doi.org/10.3969/j.issn.1000-1158.2025.05.09
SHEN Jiaming, LIU Yuan, ZHANG Ke, et al. Research on the Evaluation Method of Time Difference Measurement Capability of Ultrasonic Flow Measuring Devices Based on the Hydrostatic Towing Method[J]. Acta Metrologica Sinica. 2025, 46(5): 681-686 https://doi.org/10.3969/j.issn.1000-1158.2025.05.09
中图分类号: TB937   

参考文献

1
李坤鹏, 徐雅, 谢代梁, 等. 大口径超声波流量计内部流-声耦合特性仿真分析 [J]. 电子测量与仪器学报202034(7): 8-14.
LI K P XU Y XIE D L, et al. Simulation analysis of flow-acoustic coupling characteristics of large diameter ultrasonic flowmeter [J]. Journal of Electronic Measurement and Instrumentation202034(7): 8-14.
2
全国流量容量计量技术委员会. 非实流法校准DN1 000~DN15 000液体超声流量计校准规范:JJF 1358-2012 [S]. 2012-12-03.
3
全国水轮机标准技术委员会. 水轮机、蓄能泵和水泵水轮机流量的测量超声传播时间法: GB/Z 35717-2017 [S]. 2017-12-29.
4
TRESCH T GRUBER P STAUBLI T. Uncertainty analysis of the acoustic method with respect to absolute travel time and time difference determination [C]// IGHEM2004. Lucerne, Switzerland, 2022.
5
FANG Z H HU L MAO K, et al. Similarity judgment-based double-threshold method for time-of-flight determination in an ultrasonic gas flowmeter [J]. IEEE Transactions on Instrumentation and Measurement201867(1): 24-32.
6
陈洁, 余诗诗, 李斌,等. 基于双阈值比较法超声波流量计信号处理 [J]. 电子测量与仪器学报201327(11): 1024-1033.
CHEN J YU S S LI B, et al. Signal processing based on dual-threshold of ultrasonic flow meter [J]. Journal of Electronic Measurement and Instrumentation201327(11): 1024-1033.
7
马也驰, 赵伟国, 章圣意. 基于回波信号相似度的气体超声流量计动态阈值法研究 [J]. 计量学报202243(4): 482-488.
MA Y C ZHAO W G ZHANG S Y. Study on Dynamic Threshold Method Based on Echo Similarity for Ultrasonic Gas Flow Meter [J]. Acta Metrologica Sinica202243(4): 482-488.
8
ZHU W J XU K J FANG M, et al. Variable ratio threshold and zero-crossing detection based signal processing method for ultrasonic gas flow meter [J]. Measurement2017103: 343-352.
9
穆立彬, 徐科军, 刘博, 等. 基于可变阈值和过零检测的四声道气体超声波流量变送器 [J]. 计量学报201940(2): 266-271.
MU L B XU K J LIU B, et al. Development of four-channel ultrasonic gas flow transmitter based on variable threshold and zero-crossing detection [J]. Acta Metrologica Sinica201940(2): 266-271.
10
SUNOL F OCHOA D A GARCIA J E. High-precision time-of-flight determination algorithm for ultrasonic flow measurement [J]. IEEE Transactions on Instrumentation and Measurement201868(8): 2724-2732.
11
鲍晶晶, 蒋志迪, 刘尉悦. 一种水声声速的时频测量综合算法研究 [J]. 计量学报. 202243(3): 405-411.
BAO J J JIANG Z D LIU W Y. Research on a time-frequency measurement algorithm for underwater acoustic velocity [J]. Acta Metrologica Sinica202243(3): 405-411.
12
LI L HU Y DONG J, et al. A novel differential time-of-flight algorithm for high-precision ultrasonic gas flow measurement [J]. Journal of Instrumentation202217(5): P05019-1-P05019-17.
13
曹鹏. 大口径超声流量计时间参数校准 [D]. 保定: 河北大学, 2014.
14
STAUBLI T HEGLAND M. Current meter calibration and three-dimensional displacement effects [J]. Journal of Hydraulic Research198220(5): 453-464.
15
张亮, 孟涛, 王池, 等. 斜插式超声流量计探头插入深度影响实验研究 [J]. 仪器仪表学报201233(10): 2307-2314.
ZHANG L MENG T WANG C, et al. Probe installation effects on the accuracy of feed thru ultrasonic flowmeters [J]. Chinese Journal of Scientific Instrument201233(10): 2307-2314.
16
刘敦利, 蔡勤, 胡鹤鸣. 超声测流装置的实验室测试与优化 [J]. 计量学报202142(10): 1282-1287.
LIU D L CAI Q HU H M. Laboratory Test and Optimization of Ultrasonic Flow Measurement Device [J]. Acta Metrologica Sinica202142(10): 1282-1287.
17
李文礼,李春辉,李梦娜,等. 超声流量计实时使用中检验系统的建立及验证[J]. 计量学报202445(4): 552-558.
LI W L LI C H LI M N, et al. Establishment and Verification of Real-time In-use Measurement System for Ultrasonic Flowmeter [J]. Acta Metrologica Sinica202445(4): 552-558.
18
WILLIGEN D V NEER P V MASSAAD J, et al. Minimizing the Zero-Flow Error in Transit-Time Ultrasonic Flow Meters [C]// 2018 IEEE International Ultrasonics Symposium (IUS). Kobe, Japan, 2018.
19
MILLAN B O SALAZAR J CHAVEZ J A, et al. Zero-Flow Offset Variation in Ultrasonic Clamp-On Flowmeters Due to Inhomogeneity and Nonlinearity of Pipe Materials [J]. IEEE Transactions on Instrumentation and Measurement2017(66-11): 2845-2851.

基金

国家重点研发计划(2017YFF0206303)
中国计量科学研究院基本业务费重点领域项目(AKYZD2112)

PDF(919 KB)

Accesses

Citation

Detail

段落导航