标准铂电阻温度计在介质中的自热效应及测量方法
Self-heating Effect of Standard Platinum Resistance Thermometerin Media and Measurement Method
针对恒温槽等环境下难以实现标准铂电阻温度计准确测量的问题,提出了基于比较法和重复测量的适用于波动介质的标准铂电阻温度计自热效应的测量方法,并比较了不同介质对温度计自热效应的影响。结果表明,基于比较法和50次以上重复测量的方法可以有效减小温度波动对测量自热效应的影响;标准铂电阻温度计在常用介质中自热效应普遍达到了1.0 mK以上,显著影响了标准铂电阻温度计在量值传递中的准确性,因此,标准铂电阻温度计在量值传递中进行自热效应准确测量并进行修正是必要的。
Aiming at the problem of difficulty in accurately measuring the standard platinum resistance thermometers in environments such as constant temperature baths, a method based on comparison and repeated measurement for the self-heating effect of the standard platinum resistance thermometers suitable for fluctuating media is proposed, and the influence of different media on the self-heating effect of the thermometer are compared. The results indicate that methods based on comparison and repeated measurements of more than 50 times can effectively reduce the impact of temperature fluctuations on the measurement of self-heating effect. The self-heating effect of the standard platinum resistance thermometers in commonly used media generally reaches 1.0 mK or above, which significantly affects the accuracy of the standard platinum resistance thermometers in value transfer. Therefore, it is necessary to accurately measure and correct the self-heating effect of the standard platinum resistance thermometers in value transfer.
温度计量 / 标准铂电阻温度计 / 自热效应 / 恒温槽 / 量值传递
temperature measurement / standard platinum resistance thermometer / self-heating effect / thermostatic bath / value transfer
| 1 |
高凯,蒋庆,孙建平,等.铂丝位错特性对标准铂电阻温度计稳定性影响的研究[J].计量学报,2020,41(11):1352-1357.
|
| 2 |
邓小龙,孙建平, 乐恺,等.退火对标准铂电阻温度计性能影响的研究[J].计量学报,2015, 36(1): 26-30.
|
| 3 |
|
| 4 |
|
| 5 |
王颖文,张欣,孙建平,等.38.8344~156.5985 ℃温区温标偏差方程外推和内插研究[J].计量学报,2018,37(6):816-821.
|
| 6 |
方院生,王琦,丁诚,等.标准铂电阻温度计的自热效应研究及零功率修正方法[J].测控技术,2015,34(1):9-11.
|
| 7 |
于帆,孙建平,李婷, 等.新制标准铂电阻温度计退火特性理论模型及验证[J].计量学报,2021,42(6):759-764.
|
| 8 |
方信昀,孙建平,曾凡超, 等.高精密测温电桥的标定与评估[J].计量学报,2016,37(3):265-270.
|
| 9 |
|
| 10 |
|
| 11 |
张洁天,贾宏博,任磊.铂电阻温度传感器的自热效应[J].传感器技术,2002,21(12):13-15.
|
| 12 |
任建平,孙建平,李婷, 等.标准铂电阻温度计自热效应对测量结果的影响[J].计量学报,2021, 42(5): 589-594.
|
| 13 |
|
| 14 |
13.81~273.15 K温度计量器具:JJG 2062-1990 [S].
|
| 15 |
273.15~903.89 K温度计量器具:JJG 2020-1989 [S].
|
| 16 |
标准铂电阻温度计:JJG 160-2007 [S].
|
| 17 |
|
| 18 |
李利峰, 李锐, 闫小克, 等. 镓熔点温坪复现研究[J]. 计量学报, 2020, 41(4): 419-424.
|
/
| 〈 |
|
〉 |