Abstract:Aiming at the problem of low measurement accuracy of triangular thin-walled weir open channel flowmeter when used at non-fixed points, based on the uncertainty pre-assessment results, it is proposed to use curve fitting instead of linear interpolation to calculate the flow coefficient, and a digital output magnetostrictive water level sensor is used to measure the water head, which significantly reduces the uncertainty items that contribute more to the original method. The frequency sampling method is improved based on the Froude's similarity criterion, which improves the accuracy level of the measurement results. The uncertainty of the measurement method is improved from 1.6% to 0.56%. The calibration experiments of the triangular thin-walled weir open-channel flowmeter are carried out by the standard meter method open-channel flow rate standard device, and the experimental results show that the measurement error is reduced from 2% to less than 1% after the improved method.
高明,郭辉,贾志卓. 基于数据拟合法的三角形薄壁堰明渠流量测量不确定度优化[J]. 计量学报, 2024, 45(9): 1348-1352.
GAO Ming,GUO Hui,JIA Zhizhuo. Optimization of Flow Measurement Uncertainty in Open Channel with Triangular Thin-walled Weir Based on Data Fitting Method. Acta Metrologica Sinica, 2024, 45(9): 1348-1352.
WANG B,LIN Z P,CHEN H S. Error Analysis and Uncertainty Evaluation of Ultrasonic Open Channel Flowmeter in Parshall Flume[J]. Instrument Standardization and Metrology, 2022(6):25-27.
[3]
IMON P, ZBYNK Z. Discharge coefficient, effective head and limit head in the Kindsvater-Shen formula for small discharges measured by thin-plate weirs with a triangular notch[J]. Journal of Hydrology and Hydromechanics, 2023,71(1):35-48.
MA Z Q, SHI E J, ZHANG P, et al. Evaluation and Expression of Uncertainty of Flowmeter in Open Channel of Parshall Flume[J]. Electronics Quality, 2019(9):21-23.
XU L J, CHEN G, LI G D, et al. Numerical simulation about Rectangle Sharp-crested Weir and evaluation of free-surface [J]. Journal of Northwest A&F University, 2010,38(1):225-230.
PENG R W, ZHANG X, PENG Y H. Experimental Research on Hydraulic Characteristics of Wall Pressing Flow for Rectangle Sharp-crested Weir[J]. Journal of North China Institute of Water Conservancy and Hydroelectric Power,2012,33(3):23-26.
[9]
城市排水流堰槽测标准三角形薄壁堰:CJ/T 3008.1-1993[S]. 1993.
ZHAO W G,WANG C L, ZHU W, et al. Uncertainty Evaluation of Open-channel Discharges Measurement with the Velocity-area Method[J]. Acta Metrologica Sinica, 2015,36(5):526-529.
HUANG S Y, WEI C X, ZHENG L H. Investigation of the Steady State Method for Thermal Conductivity Measurement and its Data Processing Method[J]. Acta Metrologica Sinica, 2023, 44(4):508-512.
LIU F G,YANG C X. Study on Radiant Heat Fluxes Fitting Algorithm in Furnace of Utility Boiler[J]. Acta Metrologica Sinica, 2014, 35(5):440-444.
LI J X, WANG Y R, CHANG L, et al. Experimental Study and Theoretical Analysis of Discharge Formulae for Free Flow over Rectangular Sharp-Crested Weirs[J]. Journal of Hexi University, 2022, 38(5):25-35.
MINOO SHARIFIPOUR, HOSSEIN BONAKDARI, AMIR HOSSEIN ZAJI, et al. Numerical investigation of flow field and flowmeter accuracy in open-channel junctions[J]. Engineering Applications of Computational Fluid Mechanics, 2015,9(1):280-290.
HU B, FENG X, ZHANG P. Design of on-line Calibrating Open Channel Flowmeter Device by the Master Meter Method[J]. Metrology & Measurement Technology, 2020, 40(2):54-57.
TAN L N. Flowmeter Parshall Tank Water Level and Flow Error Measurment Uncertainty and Representation[J]. Metrology & Measurement Technique, 2015, 42(5):63-66.