All-fiber Displacement Measurement System Based on Extrinsic F-P Interferometry
MA Ying-han1,ZHANG Shu2,3,PI Lei2,YAN Han1,HU Jia-cheng1,SHI Yu-Shu2,3
1. Colloge of Metrology & Measurement Engineering,China Jiliang University,Hangzhou,Zhejiang 310018,China
2. National Institute of Metrology,Beijing 100029,China
3. Shenzhen Institute of Technology Innovation, National Institute of Metrology,Shenzhen,Guangdong 518107, China
Abstract:In order to solve the problem that the traditional separation mirror group interferometer is too large to be applied in the environment with limited space, all-fiber F-P interferometry displacement measurement technology is studied. According to the interference principle, the influence of different reflectivity conditions on the interference signal form is analyzed. When the reflectivity is 4%, the light intensity signal of multi-beam interference will be approximately a sine function, and the displacement measurement principle is verified by finite element simulation. An all-fiber displacement measurement system based on extrinsic F-P interferometry is designed and built. The experimental results show that the standard deviation of static noise voltage within 1min of the system is 23.3mV, and the linear correlation coefficient R2 of displacement measurement results between the system and commercial XL-80 laser interferometer is 1 within 1mm displacement, and the measurement repeatability of the system is better than that of commercial laser interferometer.
Yang H X, Fu H J, Hu P C, et al. Ultra-Precision and High-Speed Laser Interferometer Displacement Measurement Technology and Instrument [J]. Laser & Optoelectronics Progress, 2022, 59 (9): 305-319.
Yan H, Zhang S, Pi L, et al. Research on Resolution Evaluation Method of Nano-Positioning Stage Based on Laser Interference and Capacitive Sensor Composite Calibration Technology[J]. Acta Metrologica Sinica, 2023, 44 (8): 1196-1201.
[7]
Zhu J, Hu P, Tan J. Homodyne laser vibrometer capable of detecting nanometer displacements accurately by using optical shutters [J]. Applied optics, 2015 (34): 10196-10199.
[12]
Xu F, Ren D, Shi X, et al. High-sensitivity Fabry-Perot interferometric pressure sensor based on a nanothick silver diaphragm [J]. Optics Letters, 2012, 37 (2): 133-135.
[14]
Du B, Xu X, He J, et al. In-Fiber Collimator-Based Fabry-Perot Interferometer with Enhanced Vibration Sensitivity [J]. Sensors, 2019, 19 (2):435.
Zhang Z, Li C, Huang Z. Vibration measurement based on multiple Hilbert transform for self-mixing interferometry [J]. Optics Communications, 2019, 436: 192-196.
Shi Y S, Zhang S, Lian X Y, et al. Multi-DOF Interferometry System for Metrological Standard Device for Nano-geometrical Characteristic Size in Millimeter Range [J]. Acta Metrologica Sinica, 2020, 41 (7): 769-774.
Tan J B, Jiang Z D, Luo J B, et al. Accuracy Measurement Theory and Method for High-end Precision Equipment [J]. Bulletin of National Natural Science Foundation of China, 2022 (6): 955-962.
Shi Y S, Li W, Yu X X, et al. Research on the Traceability and Characterization Technology of 5nm Step Height Reference Material Based on Atomic Force Microscopy [J]. Chinese Journal of Scientific Instrument, 2020, 41 (3): 79-86.
Qian L S, Li Z K, Bai Y, et al. Research on the Flux Linkage Difference Measurement Method for Synchronous Measurement Based Joule Balance[J]. Acta Metrologica Sinica, 2021, 42 (9): 1121-1127.
Zhang S H, Jiang Y. Phase Demodulation Method for Non-Periodic Signal in Extrinsic Fabry-Perot Interferometric Sensor [J]. Acta Optica Sinica, 2022, 42 (9): 81-86.
Zhao C L, Li J L, Xu B, et al. Research Progress of Fiber Micro Cavity Fabry-Perot Interference Sensors [J]. Journal of Applied Sciences, 2020, 38 (2): 226-259.
[13]
Wu Y, Zhang Y, Wu J, et al. Simultaneous measurement of transverse load and temperature using hybrid structured fiber-optic Fabry-Perot interferometer [J]. Scientific Reports, 2017, 7 (1):10736.
[18]
Wang X F, Guo X Y, Wang Y, et al. All-fiber differential interferometer for nanometric displacement measurement [J]. Optics Communications, 2020, 475:126283.
[9]
Rao Y J. Recent progress in fiber-optic extrinsic Fabry-Perot interferometric sensors [J]. Optical Fiber Technical, 2006, 12 (3): 227-237.
Gao B K, Cong Z C, Sun Y. Displacement Measurement Method Based on Differential Optical Fiber Interferometer [J]. Journal of Jilin University(Information Science Edition), 2021, 39 (4): 363-367.
[15]
Tao S C, Dong X P, Lai B W. A Sensor for Simultaneous Measurement of Displacement and Temperature Based on the Fabry-Perot Effect of a Fiber Bragg Grating [J]. IEEE Sensors Journal, 2017, 17 (2): 261-266.