Abstract:With the introduction of the concept of reference material with wide particle size distribution, its determination method also needs to be clarified. For the processing and uncertainty of electron microscopic images of standard materials with wide particle size distribution, firstly, a method for boundary recognition of spherical particle images based on Hough transform circle detection was adopted to realize the correct segmentation of adhered particle images;and secondly, through numerical simulation the uncertainty of the measured value of Dv50 introduced by the number of samples was determined by the method,and the feasibility of the mentioned method was verified through comparative analysis with relevant standards; finally, the method of obtaining the uncertainty of the average particle size of the particle system from the particle size uncertainty of a single particle was proposed, and the particle size distribution range of 1~18μm was obtained. The uncertainty evaluation of glass bead particles was carried out, and the relative expanded uncertainty was 1.613%(k=2).
Zhao J Y, Yuan G M, Dong P, et al. Preparation and Measurement of PS Microspheres as Size Reference Material[J]. China Plastics Industry, 2008(6):41-44.
Zhang C, Luo Y, Yu T, et al. Estimating the Uncertainty of China Primary Standard Seawater[J]. Acta Metrologica Sinica, 2020, 41(8): 1027-1032.
[4]
Gates K, Ning C, Dilek I, et al. The uncertainty of reference standards-a guide to understanding factors impacting uncertainty, uncertainty calculations, and vendor certifications[J]. Journal of Analytical Toxicology, 2009(8): 532-539.
[5]
GB/T 19077.1—2008,粒度分析激光衍射法第1部分: 通则 [S].
[7]
JJF 1211—2008 ,激光粒度分析仪校准规范 [S].
[9]
Mazzoli A, Favoni O. Particle size, size distribution and morphological evaluation of airborne dust particles of diverse woods by Scanning Electron Microscopy and image processing program[J]. Powder Technology, 2012, 225: 65-71.
[10]
Whiting J G, Tondare V N, Scott J H, et al. Uncertainty of particle size measurements using dynamic image analysis[J]. CIRP Annals-Manufacturing Technology, 2019, 68(1): 531-534.
Hao Y H, Wu L M. Evaluation of Uncertainty for Particle Size Measurement by Micro Image Method[J]. China Powder Science and Technology, 2015, 21(3): 73-75.
Sheng K P, Jiang Z H. Measurement solid particle diameter with the internal standard method in SEM[J]. Infrared and Laser Engineering, 2008, 37(S1): 203-206.
Li Q, Li W, Shi Y S, et al. The Research of Manometer Line width Calibration Method Used by 248nm Ultraviolet Microscope[J]. Acta Metrologica Sinica, 2015, 36(1): 6-9.
[16]
ISO 14411-2-2020,Preparation of particulate reference materials-Part 2: Polydisperse spherical particles-First Edition [S].
Santo M D, Liguori C,Paolillo A, et al. Standard uncertainty evaluation in image-based measurements[J]. Measurement, 2004, 36(3): 347-358.
Cai X Y, Wei J S, Sun K X, et al. Evaluation of Uncertainty in Measurement with White light Interference System[J]. Acta Metrologica Sinica, 2021, 42(6):731-737.
Zhang L Y, He S Z, Qiu H R, et al. Uncertainty Evaluation for the Furfural Content in Transformer Oil by HPLC[J]. Acta Metrologica Sinica, 2022, 43(4): 560-564.