Flow Rate Measurement Model and Experimental Research of Unidirectional Diverter Based on Rotating Shunt
MA Long-bo1,ZHAO Jin-hui1,SUN Bin2,MEI Cong-li1,LUO Yun-xia1
1. Key Laboratory for Technology in Rural Water Management of Zhejiang Province, Zhejiang University of Water Resources and Electric Power, Hangzhou, Zhejiang 310018, China
2. College of Metrology and Measurement Engineering, China Jiliang University, Hangzhou, Zhejiang 310018, China
Abstract:To reduce the measurement error caused by the non-unidirectional diverter in the water flow standard facility, an unidirectional diverter was manufactured. The principle of the new diverter was analyzed and the flow rate measurement model also was developed based on the principle. The following conclusions were obtained that the measurement results had nothing with pulse trigger position, velocity distribution and diverting time according to the flow measurement model derivation process. The experimental research was carried out by means of the water flow standard facility. Experimental results showed that the new diverter could reduce the errors caused by the non-unidirectional diverter. So the new diverter could be used for the water flow calibration facility to measure water flow rate intead of the non-unidirectional diverter.
马龙博,赵进慧,孙斌,梅从立,罗云霞. 基于旋转分流的同向换向器流量测量模型及实验研究[J]. 计量学报, 2022, 43(6): 760-765.
MA Long-bo,ZHAO Jin-hui,SUN Bin,MEI Cong-li,LUO Yun-xia. Flow Rate Measurement Model and Experimental Research of Unidirectional Diverter Based on Rotating Shunt. Acta Metrologica Sinica, 2022, 43(6): 760-765.
[1]史慧超, 康希锐, 孟涛. 基于奇异值分解的水流量标准装置状态监测方法研究[J]. 计量学报, 2020, 41(11): 1358-1363.
Shi H C, Kang X R, Meng T. Research on State Monitoring Method of Water Flow Standard Facility Based on Singular Value Decomposition[J]. Acta Metrologica Sinica, 2020, 41(11): 1358-1363.
[2]孟涛, 王池, 陈晓铭. 流量装置中换向器检定方法的研究[J]. 计量学报, 2008, 29(5): 420-422.
Meng T, Wang C, Chen X M. Research on Verification Method of Diverters in liquid Flow Facilities[J]. Acta Metrologica Sinica, 2008, 29(5): 420-422.
[3]史振东, 李旭, 王东伟. 两种换向器在液体流量标准装置中的应用[J]. 计量技术, 2006(12):65-66.
[4]沈文新, 陆佳颖. 基于双计时原理的水表和换向器检定方法研究[J]. 计量学报, 2008, 29(5): 407-410.
Shen W X, Lu J Y. Research on the Measurement Method of Watermeter and Changeover Based on Double-timer Method[J]. Acta Metrologica Sinica, 2008, 29(5): 407-410.
[5]JJG 164—2000 液体流量标准装置[S]. 2000.
[6]马龙博, 郑建英, 赵建亮. 液体流量标准装置中开式换向器测量误差模型研究[J]. 传感技术学报, 2015, 28(4): 515-520.
Ma L B, Zheng J Y, Zhao J L. Research on the Flow Measurement Error Model of the Diverter in the Liquid Flow Calibration Facilities[J]. Chinese Journal of Sensors and Actuators, 2015, 28(4): 515-519.
[7]马龙博, 郑建英, 赵建亮. 液体流量标准装置中开式换向器测量误差实验研究[J]. 自动化仪表, 2015, 36(4): 60-62.
Ma L B, Zheng J Y, Zhao J L. Experimental Research on the Measurement Error Caused by Open Type Diverter in the Liquid Flow Calibration Facilities[J]. Process Automation Instrumentation, 2015, 36(4): 60-67.
[8]任蕾. 基于伺服电机的换向器控制系统的设计与研究[D]. 保定:河北大学, 2018.
[9]李昊予, 孟涛, 樊尚春, 等. 基于伺服电机的流量标准装置换向器精度的研究[J]. 测控技术, 2019, 38(1): 13-18.
Li H Y, Meng T, Fan S C, et al. Research on Diverter of Flow Standard Facility Based on Servo Motor[J]. Measurement &Control technology, 2019, 38(1): 13-18.
[10]孙立军, 蔡兵新, 唐冰, 等. 电动换向器双光电计时和定位方法研究[J]. 传感器与微系统, 2017, 36(7): 33-37.
Sun L J, Cai B X, Tang B, et al. Study on Double-optoelectronic Timing and Positioning Method of Electric Flow Diverter[J]. Transducer and Microsystem Technologies, 2017, 36(7): 33-37.
[11]Poeschel W, Engel R, Dopheide D. A Unique Diverter Design for Water Flow Calibration Facilities[C]// FLOMEKO 2000 Conference. Salvador, Brazil, 2000.
[12]Marfenko I, Yeh T T, Wright J. Diverter Uncertainty Less than 0. 01% for Water Flow Calibrations[C]//6th ISFFM, 2006.
[13]陈晓敏, 马龙博, 李东升. 换入-换出同向型换向器的研究[J]. 自动化仪表, 2013, 34(3): 63-65.
Chen X M, Ma L B, Li D S. Study on the Diverter that Swap in or Swap out in the Same Direction[J]. Process Automation Instrumentation, 2013, 34(3): 63-65.
[14]王建中, 倪聪明, 梁鲁林. 单向旋转式流量换向器研究[C]//2008年全国流量计量学术交流会, 中国, 南京, 2018.
[15]马龙博, 沈毅久, 郑建英. 基于MCGS的同向型换向器控制系统的设计[J]. 自动化与仪表, 2016, 11: 24-26.
Ma L B, Shen Y J, Zheng J Y. Control System Design of Fluid Diverter Based on MCGS[J]. Automation & Instrumentation, 2016, 11: 24-26.
[16]马龙博, 郑建英, 赵建亮. 基于换入换出同向方法的开式换向器设计及不确定度评定方法研究[J]. 制造业自动化, 2013, 35(11): 119-122.
Ma L B, Zheng J Y, Zhao J L. Design of the Same Direction Based on the Same Direction Swapping in and out Theory and Research on Uncertainty Calculation of the Same Direction Diverter[J]. Manufacturing Automation, 2013, 35(11): 119-122.
[17]Cheong K H, Doihara R, Shimada T, et al. Development of a gravimetric system using a conical rotating double-wing diverter for low liquid flow rate[J]. Flow Measurement and Instrumentation, 2017, 56: 1-13.