Abstract:An efficiency evaluation system of PM2.5 particle separation device based on static chamber method was established firstly. In the developed evaluation system, the different aerosol environment conforming to the measurement requirements was generated separately in the static chamber by atomizing 8 kinds of different size polystyrene particle samples. By utilizing an aerodynamic diameter spectrometer, particle concentration before and after particle separation device was measured to obtain the penetration curve of the particle separation device after data fitting. Then, evaluation experiments for a domestic and an imported particle separation devices were carried out to obtain their collecting efficiency. The study is helpful for the production and use of particle separation device, and reference for the subsequent evaluation of other kinds of particle separation devices.
[1]张国城, 赵晓宁, 靳钰. 两类PM2.5监测仪及其计量检测方法的差异 [J]. 计量技术, 2016, (8): 39-42.
Zhang G C, Zhao X N, Jin Y. Differences between two types of PM2.5 monitors and the measurement methods [J]. Measurement Technique, 2016, (8): 39-42.
[2]HJ 618-2011环境空气PM10和PM2.5的测定重量法[S]. 2011.
[3]张国城, 沈正生, 赵红达, 等. 粉尘性质对光散射式粉尘仪测量结果的影响 [J]. 计量技术, 2017, (7): 46-48.
Zhang G C, Shen Z S, Zhao H D, et al. The influence of dust properties on the measurement results of light scattering dust meter [J]. Measurement Technique, 2017, (7): 46-48.
[4]陈仲辉, 张文阁, 黄星亮, 等. PM2.5切割器切割特性研究 [J]. 中国计量, 2014, (8): 82-85.
Chen Z H, Zhang W G, Huang X L, et al. Study on cutting characteristics of PM2.5 cutter [J]. China Metrology, 2014, (8): 82-85.
[5]Lin C W, Chen T J, Huang S H, et al. Effect of Aerosol Loading on Separation Performance of PM2.5 Cyclone Separators [J]. Aerosol and Air Quality Research, 2018, (18): 1366-1374.
[6]Kuo F Y, Lin Y C, Ke L Y, et al. Detection of Particulate Matter of Size 2. 5μm with a Surface-Acoustic-Wave Sensor Combined with a Cyclone Separator [J]. Micromachines, 2018, 9(8): 398-408.
[7]Ewan C, Matthew D B, Michael S, et al. Development and characterization of a high-efficiency, aircraft-based axial cyclone cloud water collector[J]. Atmospheric Measurement Technique, 2018, (11): 5025-5048.
[8]刘佳琪,张国城,赵晓宁,等. 进气流量对PM2.5切割器捕集效率的影响分析[J]. 计量学报,2021,42(4): 532-536.
Liu J Q, Zhang G C, Zhao X N, et al. The Influence of Air Inlet Flow Rate on the Capture Efficiency of PM2.5 Cutter [J]. Acta Metrologica Sinica, 2021, 42(4): 532-536.
[9]Environmental Protection Agency. Title 40: Protection of Environment, Part 53-Ambient Air Monitoring Reference and Equivalent Methods, Subpart F-Procedures for Testing Performance Characteristics of Class II Equivalent Methods for PM2.5 [S]. 2014.
[10]HJ/T 93-2003PM10 采样器技术要求及检测方法 [S]. 2003.
[11]HJ 93-2013环境空气颗粒物(PM10和PM2.5)采样器技术要求及检测方法 [S]. 2013.
[12]张文阁, 刘巍, 许萧, 等. PM2.5监测仪检测用国家一级标准物质的研制 [J]. 计量学报, 2019, 40(1): 159-163.
Zhang W G, Liu W, Xu X, et al. Preparation of National Primary Reference Materials for PM2.5 Monitors [J]. Acta Metrologica Sinica, 2019, 40(1): 159-163.
[13]Peng D, Jianguo L, Huaqiao G, et al. Development of a static test apparatus for evaluating the performance of three PM2.5 separators commonly used in China [J]. Journal of Environmental Sciences, 2020, 32: 238-249.
[14]许金鑫, 由强. 任意阶次多项式最小二乘拟合不确定度计算方法与最佳拟合阶次分析 [J]. 计量学报, 2020, 41(3): 388-392.
Xu J X, You Q. Uncertainty Calculation for Arbitrary Order Polynomial Least-square Fitting and Analysis of the Best Fitting Order [J]. Acta Metrologica Sinica, 2020, 41(3): 388-392.
[15]李新颖, 刘凯, 黄海燕. 多线函数法在曲线拟合中的应用研究[J]. 计量学报, 2018, 39(5): 716-719.
Li X Y, Liu K, Huang H Y. Application of Multi-line Function Method in Curve Fitting [J]. Acta Metrologica Sinica, 2018, 39(5): 716-719.
[16]吴丹,张国城,赵晓宁. 光散射法颗粒物监测仪粒径识别检测装置的搭建及方法研究[J]. 计量学报, 2021, 42 (3): 388-394.
Wu D, Zhang G C, Zhao X N. Research on Construction and Method of Particle Size Recognition and Detection Device for Light Scattering Particles Monitor[J]. Acta Metrologica Sinica, 2021, 42 (3): 388-394.