三天线法环天线校准系统建立及测量结果不确定度评定

秦瑶,吴艳丽,刘潇

计量学报 ›› 2021, Vol. 42 ›› Issue (10) : 1367-1371.

PDF(1144 KB)
PDF(1144 KB)
计量学报 ›› 2021, Vol. 42 ›› Issue (10) : 1367-1371. DOI: 10.3969/j.issn.1000-1158.2021.10.16
无线电、时间频率计量

三天线法环天线校准系统建立及测量结果不确定度评定

  • 秦瑶1,吴艳丽2,刘潇3
作者信息 +

The Loop Antenna Calibration System using the Three-Antenna Method and the Uncertainty Estimation for the Measurement Results

  • QIN Yao1,WU Yan-li2,LIU Xiao3
Author information +
文章历史 +

摘要

在350kHz~30MHz频段内,为了准确得到环天线所处位置的场强,环天线的天线系数需要校准。三天线法是一种校准天线系数的绝对方法,需要3个环天线,两两组对测量,且不需要任何参考标准。介绍了三天线法校准环天线的原理,基于矢量网络分析仪建立校准系统,并评定校准系统的测量结果不确定度。基于K(i,j)的计算公式复杂,很难计算出其引入的不确定度,因此采用数字电磁学代码(NEC)建模评定K(i,j)的不确定度。评定结果表明,在350kHz~30MHz频段内4个典型频点的扩展不确定度小于0.81dB(k=2)。

Abstract

In the 350kHz~30MHz frequency band, in order to accurately obtain the field strength where the loop antenna is located, the antenna factor of the loop antenna needs to be calibrated. The three-antenna method is an absolute method for calibrating the antenna factor.Antenna calibration using the three-antenna method requires three antennas to form three antenna pairs and does not require any reference standard.TAM is discussed in detail, a calibration system based on a vector network analyzer is set up, and the standard uncertainty of the calibration system is evaluated.It is not possible to derive the uncertainty introduced by the calculation formula based on K(i,j). Therefore, the numerical electromagnetics code (NEC) simulations are used to evaluate the uncertainty of K(i,j). The evaluation results show that the extended uncertainty of the four typical frequency points in the 350kHz~30MHz frequency band is less than 0.81dB (k=2).

关键词

计量学 / 环天线 / 天线系数 / 三天线法 / 校准 / 标准不确定度

Key words

metrology / loop antenna / antenna factor / threee-antenna method / calibration / uncertainy

引用本文

导出引用
秦瑶,吴艳丽,刘潇. 三天线法环天线校准系统建立及测量结果不确定度评定[J]. 计量学报. 2021, 42(10): 1367-1371 https://doi.org/10.3969/j.issn.1000-1158.2021.10.16
QIN Yao,WU Yan-li,LIU Xiao. The Loop Antenna Calibration System using the Three-Antenna Method and the Uncertainty Estimation for the Measurement Results[J]. Acta Metrologica Sinica. 2021, 42(10): 1367-1371 https://doi.org/10.3969/j.issn.1000-1158.2021.10.16
中图分类号: TB973   

参考文献

[1]刘潇,吴艳丽,秦瑶,等. TEM室法环天线校准系统建立及测量结果不确定度评定[J]. 计量学报, 2021, 42(8): 1061-1067.
Liu X,Wu Y L,Qin Y, et al. The Loop Antenna Calibration System Using the TEM Method and the Uncertainty Estimation for the Measurement Results[J].  Acta Metrologica Sinica, 2021, 42(8): 1061-1067.
[2]孟东林, 吴钒, 王维龙. NIM球面近场法天线校准装置的测量不确定度评定 [J]. 计量学报, 2017, 38 (6):758-762.
Meng D L, Wu F, Wang W L. Uncertainty Evaluation of NIM Spherical Near-field Antenna Calibration Facility [J].Acta Metrologica Sinica,2017, 38(6):758-762.
[3]梁群庄, 万今明, 吕继方, 等. EMC环形天线系统测量不确定度评定 [J]. 电子测量技术, 2018, 41 (14): 26-29.
Liang Q Z, Wan J M, Lü J F, et al. Assessment for measurement uncertainty of loop antenna system for EMC[J]. Electronic Measurement Technology, 2018, 41 (14): 26-29.
[4]胡荣飞, 杨娟. 电小环天线 [J]. 中国无线电, 2018, (7): 30-31.
[5]王华建, 王英翔. 天线系数的计算与使用 [J]. 中国无线电, 2010, (7): 27-30.
[6]高刚, 周忠元, 景莘慧. 环天线校准技术研究 [J]. 安全与电磁兼容, 2014 ,(3): 63-65.
Gao G, Zhong Z Y, Jing S H. Research on Loop Antenna Calibration Methods [J]. Safety EMC, 2014, (3): 63-65.
[7]刘鹏, 刘君荣, 梁琼崇. 基于网络分析仪的EMC测量天线校准方法研究 [J]. 电子产品可靠性与环境试验, 2017, 35 (2): 39-44.
Liu P, Liu J R, Liang Q C.The Study of EMC Measurement Antenna Calibration Method Based on Network Analyzer [J]. Electronic Product Reliability and Environmental Testing, 2017,35 (2): 39-44.
[8]CISPR 16-1-6 Specification for radio disturbance and immunity measuring apparatus and methods-Part 1-6: Radio disturbance and immunity measuring apparatus-EMC antenna calibration-Calibration methods for the frequency rang 9kHz to 30MHz[S].2017.
[9]Arthur D C, Ji Y, Daly M P J. A simplified method for the measurement of magnetic loop antenna factor [C]//2008 Conference on Precision Electromagnetic Measurements Digest.Broomfield,Colorado,USA,2008.
[10]Ishii M, Komiyama K. A measurement method for magnetic antenna factor of small circular loop antenna by 3-antenna method [C]//2003 Information and Communication Engineers.Hamamatsu, Japan,2003.
[11]胡白涛, 洪力, 李渤. 环天线校准方法 [J]. 现代测量与实验室管理, 2007, 15 (5): 3-4.
Hu B T, Hong L, Li B. Calibration Method of Loop Antenna [J]. Advanced Measurement and Laboratory Management, 2007, 15 (5): 3-4.
[12] 陈军, 宋振飞, 万发雨. 外推法天线增益测量的核心算法及实验研究[J]. 计量学报, 2021, 42(6): 793-798.
Chen J, Song Z F, Wan F Y. The Core Algorithm and Experimental Research of Antenna Gain Measurement by Extrapolation[J]. Acta Metrologica Sinica, 2021, 42(6): 793-798.
[13]蒋廷勇,燕有杰,刘小龙,等.短电磁脉冲标准场装置实验室比对[J].计量学报,2019, 40 (6): 1107-1111.
Jiang T Y, Yan Y J, Liu X L,et al. Inter-laboratory Comparisons of Standard Facilities for Short Pulse E-field[J].Acta Metrologica Sinica, 2019, 40 (6): 1107-1111.
[14]刘潇,李渤,谢鸣.基于TEM小室的探头校准系统不确定度评定[J].计量学报, 2015, 36(3): 318-323.
Liu X, Li B, Xie M. The Uncertainty Estimation for the Probe Calibration Results Employing a TEM Cell [J]. Acta Metrologica Sinica, 2015, 36(3):318-323.
[15]CISPR 16-1-5 Specification for radio disturbance and immunity measuring apparatus and methods-Part 1-5: Radio disturbance and immunity measuring apparatus-Antenna calibration sites and refer-ence test sites for 5MHz to 18GHz[S]. 2014.

基金

国家自然科学基金(86567370);国家自然科学基金青年基金(56312680);国家重点研发计划 (2018YFF0212102);中国科学研究院能力提升项目(ANL1906);河南省教育厅高等学校重点科研项目(20A510004);粮食信息处理与控制教育部重点实验室开放课题(KFJJ-2018-102)