Abstract:In order to prolong the service life of the fixed point blackbody and simplify the use process, based on the design and use experience of the heat pipe blackbody and the traditional graphite crucible blackbody, an improved package fixed point blackbody was developed. The second-class standard platinum resistance and transfer radiation thermometer are used to carry out the reproduction tests of the tin fixed-point blackbody. After more than 20 cycles of melting and freezing, there is no rupture and metal leakage in the improved encapsulated fixed point blackbody. The average value of multiple tests is 231.909℃, with the help of the standard platinum resistance thermometer, and the expanded uncertainty is 0.015℃(k=2). While with the fixed point blackbody used to calibrate the transfer radiation thermometer, the average value of multiple tests is 231.85℃, and the expanded uncertainty is 0.096℃(k=2).
[1]董磊, 蔡静, 孟苏. 浴式黑体辐射源校准方法研究[J]. 计测技术, 2015(1):33-37.
Dong L, Cai J, Meng S. Research on calibration methods of bath blackbody source[J]. Metrology Measurement Technology, 2015(1):33-37.
[2]张磊, 郑小兵, 张黎明,等. 定量化红外遥感应用的高精度水浴黑体[J]. 光学技术, 2007, 33(2):245-248.
Zhang L, Zheng X B, Zhang L M,et al. High accuracy water bath blackbody based on the information quantification of infrared remote sensing[J]. Optical technique, 2007, 33(2):245-248.
[3]Machin G , Chu B . High quality blackbody sources for infra-red thermometry and thermography between -40℃ and 1000℃[J]. The Imaging Science Journal, 2000, 48(1):15-22.
[4]Hill K D , Woods D J. Characterizing the NRC blackbody sources for radiation thermometry from 150℃ to 962℃[J]. International Journal of Thermophysics, 2009, 30(1):105-123.
[5]黄燊彦, 郝小鹏, 王景辉,等. 铯、钠热管标准黑体辐射源研制及性能评价[J]. 计量学报, 2014, 35(2):120-124.
Huang S Y, Hao X P, Wang J H, et al. Development and characterization of Cesium, Sodium heat pipe standard blackbody radiation sources[J]. Acta Metrologica Sinica, 2014, 35(2): 120-124.
[6]孔令辉. 中温固定点黑体辐射源研制及性能评价[D]. 成都:成都理工大学, 2013.
[7]吴继彧, 原遵东, 段宇宁,等. 辐射法锌凝固点复现及其不确定度评定[J]. 现代计量测试, 2000,(5):9-13.
Wu J Y, Yuan Z D, Duan Y N, et al. Realization of Zinc fixed-point by radiation thermometry and its uncertainty evaluation[J].Modern Measurement and Test, 2000,(5):9-13.
[8]赵琪, 李大今, 原遵东,等. 辐射法复现铜凝固点[J]. 计量学报, 1987,8(1):3-8.
Zhao Q, Li D J, Yuan Z D, et al. The realization of the copper freezing point by pyrometry[J]. Acta Metrologica Sinica, 1987,8(1):3-8.
[9]宋健, 郝小鹏, 丁雷,等. 真空低背景红外高光谱亮温计量标准装置研制[J]. 红外与激光工程, 2019, 48(10) :26-32.
Song J, Hao X P, Ding L, et al. Development of reduced background vacuum infrared hyperspectral radiance temperature standard facility[J]. Infrared and Laser Engineering, 2019, 48(10):26-32.
[10]张建岭. 热力学温度测量中的滤光片辐射计特性研究[D]. 北京:华北电力大学, 2012.
[11]Abasov M Y , Gerasimov S F , Ivanova A G , et al. Measurement of Al freezing-point temperature: effect of initiation process[J]. International Journal of Thermophysics, 2010, 31(8-9):1663-1675.
[12]Khlevnoy B B , Yamada Y , Samoylov I A G L. Comparison of Re-C fixed-point cells and their T90 temperatures between NMIJ and VNIIOFI[J]. International Journal of Thermophysics, 2011,32:1753-1762.
[13]Khlevnoy B B , Grigoryeva I A, Otryaskin D A. Development and investigation of WC-C fixed-point cells[J]. Metrologia, 2012, 49(2):S59-S67.
[14]Anhalt K, Wang Y F, Yamada Y, et al. Large and small aperture fixed-point cells of Cu, Pt-C, and Re-C[J]. International Journal of Thermophysics, 2008, 29(3):969-983.
[15]Battuello M, Girard F, Florio M. Small copper fixed-point cells of the hybrid type to be used in place of normal larger cells[J]. Measurement Science and Technology, 2012, 23:105002.
[16]Wang T, Lowe D, Machin G. Manufacturing of MC eutectics and reproducibility of Pt-C eutectic fixed points using a thermogauge furnace[J]. International Journal of Thermophysics, 2009, 30(1):59-68.
[17]李凯, 郝小鹏, 宋健,等. 真空汞固定点黑体辐射源的设计与研制[J]. 计量学报, 2020, 41(4):413-418.
Li K, Hao X P, Song J, et al. Design and development of vacuum mercury fixed point blackbody radiation source[J]. Acta Metrologica Sinica, 2020, 41(4):413-418.
[18]文平, 郝小鹏, 孙建平,等. 基于微型镓基共晶固定点的温度传感器在轨校准方法研究[J]. 计量学报, 2019, 40(4): 595-602.
Wen P, Hao X P, Sun J P, et al. On-orbit calibration of temperature sensor based on miniature gallium-based alloy fixed point[J]. Acta Metrologica Sinica, 2019, 40(4): 595-602.
[19]胡朝云, 郝小鹏, 宋健,等. 红外高光谱大气探测仪星载固定点黑体辐射源的研制[J]. 计量学报, 2019, 40(2): 232-239.
Hu C Y, Hao X P, Song J, et al. Development of blackbody radiation sources at fixed point on satellite of infrared hyperspectral atmospheric detector[J]. Acta Metrologica Sinica, 2019, 40(2): 232-239.
[20]刁福广, 蔡晋辉, 孙建平,等. Ga-In-Sn微型共晶点相变特性研究[J]. 计量学报, 2019, 40(3):421-426.
Diao F G, Cai J H, Sun J P, et al. Study on phase transition characteristic of mini Ga-In-Sn eutectic fixed point[J]. Acta Metrologica Sinica, 2019, 40(3):421-426.
[21]Vasil'ev E V, Ignatov A A, Kalinin M I, et al. Investigation of the reproducibility of melting and freezing curves for tin in a miniature cell[J]. Measurement techniques, 2018, 61(5):494-500.