Abstract:To study the meters factor of clamp-on type ultrasonic flowmeter under different pipe diameters with different flow velocity points, six pipes are selected within the pipe diameter between 100mm to 400mm and six flow velocity points are selected within the range of 0.3~3m/s to experimental study. The results of experiments show that the error of every flow point changed slightly under the same pipe diameter. With the increase of pipe diameter, the error under the same flow point decreases and the meters factor increases. By establishing mathematical model, the meters factors are compared between the mathematical model and the experimental study, it proves that of using the mathematical model to derive the meters factor under different pipe diameters is feasible, it can improve the measurement accuracy of the flowmeter under different pipe diameters.
[1]阎玉舜, 姜天仕. 超声工业测量技术应用的进展[J]. 声学技术, 2014(1): 5-7.
Yan Y S, Jiang T S. Progress in application of ultrasonic industrial measurement technology[J]. Acoustic Technology, 2014(1): 5-7.
[2]蔡武昌. 超声流量计的现状和进展[J]. 世界仪表与自动化, 1998,(2): 46-48.
[3]段慧明, 翟秀贞. 超声流量计的应用与展望[J]. 计量技术, 2015(6): 23-26.
[4]Lynnworth L C, Liu Y. Ultrasonic flowmeters: half century progress report[J]. Ultrasonics, 2016, 44(1): 1371-1378.
[5]Dimitrijeviib B, Pavloviiv V. Ultrasonic Fluid Flow Measurement Methods, an Overview[J]. Facta Universitatis Series: Electronics and Energetics, 1995. 8(2): 299-315.
[6]王自和. 超声波流量测量[J]. 国外计量, 2005(9): 36-40.
[7]Sanderson M L, Hemp J. Ultrasonic flowmeters a review of the state of the art[C]//International Conference on Advances in Flow Measurement Techniques. Coventry, England, 2001.
[8]Kirillov K M, Nazarov A D, Mamonov V N, et al. An ultrasonic flowmeter for viscous liquid[J]. Measurement Techniques, 2014, 57(5): 533-536.
[9]Sejong Chun, Byung-Ro Yoon, Duck-Ki Lee, et al. Correction of flow metering coefficients by using multi-dimensional non-linear curve fitting[J]. Journalof Mechanical Science and Technology, 2012, 26(11): 3479-3489.
[10]刘敦利, 蔡勤. 管道对超声波流量计计量准确度的影响分析[J]. 中国测试, 2017, 43(7): 25-28.
Liu D L, Cai Q. Analysis of the influence of pipeline on the measurement accuracy of the ultrasonic flowmeter[J]. China Measurement & Test, 2017, 43(7): 25-28.
[11]王振, 邹海波, 孟涛, 等. 影响外夹超声流量计测量准确度的实验研究[J]. 计量学报, 2012, 33(z1): 26-28.
Wang Z, Zhou H B, Meng T, et al. Experimental Study on Measurement Accurancy Influence of Clamp-on Type Ultrasonic Flowmeter[J]. Acta Metrologica Sinica, 2012, 33(z1): 26-28.
[12]刘敦利. 传感器安装距离对超声波流量计计量精度的影响分析[J]. 工业计量, 2015(3): 29-30.
Liu D L. Analysis of the influence of sensor installation distance on measurement accuracy of ultrasonic flowmeter[J]. Industrial Measurement, 2015(3): 29-30.
[13]国家市场监督管理总局. JJG 1030-2007 超声流量计检定规程[S]. 2007.
[14]胡江顺, 何松杰. 管道参数对便携式超声波流量计测量的影响[J]. 计量技术, 2011(9): 7-9.
Hu J S, He S J. The influence of pipe parameterson the measurement of portable ultrasonic flowmeter[J]. Measurement Technique, 2011(9): 7-9.
[15]李晓宇, 王顺利. 管道壁厚对便携式超声波流量计检定结果的影响分析[J]. 中国计量, 2015(8): 95-96.
Li X Y, Wang S L. Analysis of the influence of pipe wall thickness on the verification results of portable ultrasonic flowmeter[J]. China Measurement, 2015,(8): 95-96.
[16]国家市场监督管理总局. JJF 1027-1991 测量误差及数据处理[S]. 1991.
[17]雷镇嘉, 刘敦利. 外夹式超声流量计安装管径与仪表系数的关系研究[J]. 计量技术, 2018,(3): 10-13.
Lei Z J, Liu D L. Study on the relationship between meter factor with the pipe diameter of clamp-on type ultrasonic flowmeter[J]. Measurement Technique, 2018,(3): 10-13.
[18]王鹏, 刘敦利, 许德福, 等. 外夹超声流量计单声道测量理论分析与实验[J]. 计量与测试技术, 2019, 46(3): 22-26.
Wang P, Liu D L, Xu D F, et al. Theoretical analysisand experiment of single channel measurementof clamp-on ultrasonic flowmeter[J]. Metrology and measurement Technique, 2019, 46(3), 22-26.