摘要

圆分度角用排列互比法测量时,一般选用较大的测量间隔角。为了测出大间隔角范围内的小角度偏差,提出了分段内插测量法。由于组成间隔角的两角位置的偏差已由排列互比法测出,因此可作为控制点。通过和小角度陪检工具的连续比较,消减陪检工具角度偏差的影响,得到间隔角范围内的小角度偏差。分段内插测量法是排列互比法的扩展与补充。

Abstract

The circle indexing angle is generally measured by selected a large interval angle when using permutation intercomparison method. In order to measure the deviation of a small angle which is in the range of the large interval angle, a piecewise interpolation measurement is proposed. Considering which have been measured by the permutation intercomparison method, the deviation of the two angle position composing the interval angle can be used as control points. In this interval angle, the small angle deviation can be observed through continuous comparison with small angle inspection tools. In conclusion, the piecewise interpolation measurement is the extension and supplement of the permutation intercomparison method.

关键词

计量学 / 圆分度角 / 分段 / 内插 / 小间隔角 / 测量

Key words

metrology / circular indexing angle / piecewise / interpolation / small interval angle / measurement

引用本文

导出引用
王蕾,张忠武,王震,孙方金,王春喜,张铁犁,刘晓旭. 圆分度角测量检定中的分段内插测量法[J]. 计量学报. 2020, 41(1): 6-10 https://doi.org/10.3969/j.issn.1000-1158.2020.01.02
WANG Lei,ZHANG Zhong-wu,WANG Zhen,SUN Fang-jin,WANG Chun-xi,ZANG Tie-li,LIU Xiao-xu. Piecewise Interpolation Measurement in Circular Indexing Angle Measurement Verification[J]. Acta Metrologica Sinica. 2020, 41(1): 6-10 https://doi.org/10.3969/j.issn.1000-1158.2020.01.02
中图分类号: TB922   

参考文献

[1]孙方金, 陈世杰. 精密轴系回转精度测试[M]. 哈尔滨: 哈尔滨工业大学出版社, 1997.
[2]JJG 462—2007多齿分度台[S].
[3]谢长文, 范天泉, 曹学东, 等. 排列互比法用于测角时测量结果及测量误差的计算[J]. 计量学报, 1998, 19(3): 190-193.
Xie C W, Fan T Q, Cao X D, et al. Calculation of Permutation intercomparison method using in measurem-ent results and measurement errors in angle measurement[J]. Acta Metrologica Sinica, 1998, 19(3): 190-193.
[4]花国梁. 精密测量技术[M]. 北京: 中国计量出版社, 1990.
[5]Arif Sanjid M. Improved direct comparison calibration of small angle blocks [J]. Measurement, 2013, 46(1): 646-653.
[6]孙方金, 王蕾, 孟庆生, 等. 板式空心角锥棱镜的研制[J]. 宇航计测技术, 2017, 37(4): 8-11.
Sun F J, Wang L, Meng Q S, et al. Development of hollow cube corner retro-reflector of panel structure [J]. Journal of Astronautic Metrology and Measurement, 2017, 37(4): 8-11.
[7]林家明, 曹根瑞, 苏大图. 高精度标准小角度发生器的研制、 应用与传递-系列光学角规[J]. 光学技术, 1996, 2: 41-44.
Lin J M, Cao G R, Su D T. Researching, using and transmission of high precision standard small angle generator-a series of optical angle gauge [J]. Optical Technology, 1996, (2):41-44.
[8]张俊杰, 王震, 李政阳, 等. CCD自准直仪示值漂移的自校准系统[J]. 计量学报, 2011, 32(2): 123-125.
Zhang J J, Wang Z, Li Z Y, et al. Self-calibration System for the Value Drifts of CCD Autocollimator [J]. Acta Metrologica Sinica, 2011, 32(2): 123-125.
[9]孙方金. 角度计量测试技术——排列互比法[J]. 中国计量, 1997, (12): 49-51.
[10]任顺清, 赵洪波, 程源, 等. 递推最小二乘法在角位置误差检测中的应用[J]. 计测技术, 2009, 29(5): 8-11.
Ren S Q, Zhao H B, Cheng Y, et al. Application of recursive least square method to angular error checking[J]. Metrology & Measurement Technology, 2009, 29(5): 8-11.
[11]陆德基, 谢长文, 范天泉, 等. 排列互比法用于超精测角时数据处理方法的研究[J]. 计量技术, 1997, (9): 27-29.
Lu D J, Xie C W, Fan T Q, et al. Investigations on data processing method of permutation intercomparision Method to superprecision angle Measuring[J]. Measurement Technique, 1997, (9): 27-29.
[12]Shi Y C. Measurement of centring error of serrated-tooth indexing table [J]. Measurement Technology and Intelligent Instruments, 1993, 9:829-832.

基金

国家重点研发计划(2016YFF0200700)

PDF(596 KB)

Accesses

Citation

Detail

段落导航
相关文章

/