Abstract:Since electrical capacitance tomography system with fixed electrodes has the drawbacks of limited measurement data and image distortion caused by the electrodes position, a novel electrical capacitance tomography model is proposed based on 16 rotating electrodes, together with a corresponding image fusion method. This model rotates a 16-electrode electrical capacitance tomography sensor four times, and the resulted measurements are used to reconstruct images by using linear back-projection and modified conjugate gradient (MCG) respectively, and thereafter wavelet transform is performed on the 5 reconstructed images, and the resulted low frequency and high frequency components are fused with the weighted average method and the principal component analysis (PCA) respectively. Experimental results show that by increasing the number of measured capacitance values and processing data with image fusion method, the proposed rotating ECT model can obviously improve the quality of reconstructed image and reduce the imaging error.
[1]马敏, 高振福, 王化祥, 等. 基于BP神经网络的ECT图像重建算法[J]. 计量学报, 2013, 34(6):524-528.
[2]Xie C G, Plaskowski A, Beck M S. 8-electrode CapacitanceSystemforTwo-component Flow Identification Part 2:Flow Regime identification[J]. IEE Proceedings A, 1992, 1: 184-190.
[3]Wang H X, Xin S H, Zhang X H. New progress of the digital electrical capacitance tomography system for gas/liquid two phase flow[C]// 2009 IEEE International Workshop on Imaging Systems and Techniques, IST 2009-Proceedings. Hong Kong, China, 2009: 37-40.
[4]Yang Y J, Peng L H. A configurable electrical capacitance tomography system using a combining electrode strategy[J]. Measurement Science Technology, 2013, 24(7):1-11.
[5]马敏, 张彩霞, 姬晶晶, 等. 改进的共轭梯度算法的图像重建算法[J]. 计量学报, 2013, 34(1):27-30.
[6]周苗苗. 基于ECT的航空发动机尾气检测系统的图像重建研究[D]. 天津:中国民航大学, 2015.
[7]王洪斌,王世豪,籍冰朔, 等. 基于改进多阈值小波包的去噪算法及应用[J]. 计量学报, 2016, 37(2): 205-208.
[8]陶红歌, 陈焕新, 谢军龙, 等. 基于面积加权平均速度和质量加权平均速度的流体流动均匀性指标探讨[J]. 化工学报, 2010, 61(S2):116-120.
[9]刘靖, 孙猛, 刘石, 等. 电容层析成像技术测量煤粉输送浓度的研究[J]. 计量学报, 2011, 32(1):31-35.
[10]Liu L, Shao F Q. Convergence analysis for modified conjugate gradient in electromagnetic tomography[C]// 2011 International Conference on Electric Information and Control Engineering, ICEICE 2011-Proceedings. Wuhan, China, 2011: 3086-3089.
[11]Liu C H, Xu L J, Cao Z H. Measurement of nonuniform temperature and concentration distribution by combining line-of-sight tunable diode laser absorption spectroscopy with regularization methods[J]. Applied Optics, 2013, 52(20):4827-4842.
[12]王化祥, 汪婧, 胡理, 等. ERT/ECT双模态敏感阵列电极优化设计[J]. 天津大学学报, 2008, 41(8):911-918.