1.School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China
2.Science and Technology on Inertial Laboratory, Beijing 100191, China
3.Key Laboratory of Micro-nano Measurement-Manipulation and Physics, Beijing 100191, China
Abstract:The essay established mathematical models of two kinds of saddle shim coils under the Cartesian coordinates based on the Biot-Savart Law,the general characteristic of magnetic field distribution has been numerical analyzed in radial direction. Meanwhile, utilizing Matlab software to optimize the coils parameters under theoretical deduced optimum structure, the magnetic field uniformity area and the deviation relative to center magnetic field intensity in axis and cubic space produced by these two kinds of saddle coils are compared under the optimum magnetic uniformity .Additionally, homogeneous magnetic field effective space area of these two kinds of saddle coils is given on the condition of its relative deviation less than 1%,which provided the theoretical basis and reference for the design and research of the radial dimensional of magnetic field compensation system.
丁莹,董全林,赵伟霞,李茹杰,房建成. 两类鞍形线圈产生磁场均匀性效能的研究[J]. 计量学报, 2016, 37(6): 638-643.
DING Ying,DONG Quan-lin,ZHAO Wei-xia,LI Ru-jie,FANG Jian-cheng. Research on magnetic uniformity Performance of two kinds of saddle Coils for Magnetic Shielding. Acta Metrologica Sinica, 2016, 37(6): 638-643.
[1]赵永明, 徐云飞, 吴艳,等.通过补偿法获得零磁场环境[J].浙江大学学报(理学版),2006, 33(01):44-47.
[2]董全林, 刘雪萍, 张春熹, 等. 双圈共轴线圈产生错位对激励磁场的影响[J]. 计量学报. 2013, 34(6): 573-578.
[3]陆小松. 基于冷原子系综的非经典关联光子源研究[D]. 合肥:中国科学技术大学, 2009.
[4]刘坤, 张松勇, 顾伟. 方形亥姆霍兹线圈磁场系统均匀性分析[J]. 现代电子技术, 2012,35(7):190-195.
[5]李国丽, 李剑平, 王群京, 等. 外磁场驱动的无线内窥镜磁场线圈的设计方法研究[J]. 中国科学技术大学学报, 2008, (03): 272-276.
[6]Wang X Z, Hao J C,Yu Y, et al. The Design of Coil Assembly Producing Uniform Magnetic Field Using in Plasma Propulsion System[C]// IEEE 19th International Vacuum Nanoelectronics Conference & 50th International Field Emission Symposium, Guilin, 2006.
[7]Salmon C E G, Vidoto E L G, Martins M J, et al. Optimization of Saddle Coils for Magnetic Resonance Imaging[J].Brazilian Journal of Physics, 2006, 36(1A):4-8.
[8]赵伟霞, 董全林, 孙茂多, 等. 一种圆鞍形磁屏蔽线圈的设计与性能研究[J]. 计量学报, 2015,36(5):540-545.