Abstract:The design method of injection current probe calibration-jig is introduced. The influence of the gap between the probe and the jig on transmission performance is analyzed by numerical simulation, and the key size of the jig is determined by means of parameter optimization. The design method is verified by measurements.
[1]ISO/FDIS 11452-4. Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy—Part 4: Harness excitation methods[S]. 2011.
[2]MIL-STD-461F. Requirements for the control of electromagnetic interference characteristics of subsystems and equipment[S]. 2007.
[3]郑兆翁. 同轴式TEM模通用无源器件[M]. 北京:人民邮电出版社, 1983.
[4]宋盛义,冯晓晖,周之奎,等. 共顶点同轴圆锥形及圆盘形传输线的电参数计算公式[J]. 强激光与粒子束,2004, (02): 256-260.
[5]Grassi F, Marliani F, Pignari S A. Circuit Modeling of Injection Probes for Bulk Current Injection[J]. IEEE Transactions on Electromagnetic Compatibility, 2007, 49(3): 563-576.
[6]邱成悌,蒋全兴. 电子设备结构设计原理[M]. 南京:东南大学出版社, 2001.
[7]赵如如. 偏磁场与开气隙对磁性材料干扰抑制特性影响的研究[D]. 东南大学, 2012.