Abstract:To propose that highpurity water which producted by microfilter,recerse osmosis and electrodeionzation technology is used as calibration medium and as a substitute for tapwaterTo correcte the density of water for factors as the water isotopic abundance,teperature gradient and dissolved air,the isotopic abundance,teperature gradient and atmosphere environmental parameters (t,p,RH) are measuredThe water quality report shows that the water be producted is in accord with the GB/T 11446.1 EW-I standardThe standard measurement uncertainty of water density is reduced to 7×10-3kg/m3,and the measurement uncertainty of the volume primary standard Urel is less than 3×10-5(k=3).
郭立功,刘子勇,王金涛,佟林,暴雪松. 检定介质制备与静力称重法容量测量不确定度研究[J]. 计量学报, 2013, 34(6): 537-540.
GUO Li-gong,LIU Zi-yong,WANG Jin-tao,Tong Lin,Bao Xu-song. Study on Uncertainty of Volume Measerment by Hydrostatic Weighing Method and Production of Calibration Medium. Acta Metrologica Sinica, 2013, 34(6): 537-540.
[1]郭立功,刘子勇,等.5~2000L容量基准装置技术改造[J].计量学报,2012,33(5A),174-176.
[2]JJG 259—2005 标准金属量器[S].
[3]Maldonado J M,et al.International comparison of volume measurement standards at 50 l at the CENAM (Mexico),PTB (Germany),Measurement Canada and NIST (USA)[J].Metrologia,2002,39:91-95.
[4]Man J, Arias R, et al. Final report on APMP key comparison of volume of liquids at 20 L and 100 mL: APMP.M.FF-K4[J].Metrologia,2011,48:07001.
[5]GB/T 6682-2008 分析实验室用水规格和试验方法[S].
[6]ISO 3696:1987,Water for analytical laboratory use – Specification and test methods[S].
[7]Davis R S.Equation for Determination of the Density of Moist Air[J].Metrologia,1992,29:67-70.
[8]Tanaka M,et al.Recommended table for the density of water between 0°C and 40° C based on recent experimental reports[J].Metrologia,2001,38,301-309.
[9]Elsa Batista, Richard Paton. The Selection of Water Property Formulae for Volume and FlowCalibration[J].Metrologia.2007,44,453-463.
[10]Bignell N.The Effect of Dissolved Air on the Density of Water[J].Metrologia,1983,19(2),57-59.
[11]JF 1059—1999 测量不确定度评定与表示指南[S].