基于低温辐射计的光探测器响应度基准

林延东,吕亮

计量学报 ›› 2012, Vol. 33 ›› Issue (6) : 494-498.

PDF(347 KB)
PDF(347 KB)
计量学报 ›› 2012, Vol. 33 ›› Issue (6) : 494-498. DOI: 10.3969/j.issn.1000-1158.2012.06.04

基于低温辐射计的光探测器响应度基准

  • 林延东,吕亮
作者信息 +

Responsivity Standard of Optical Detector Based on the Cryogenic Radiometer

  • LIN Yan-dong,Lü Liang
Author information +
文章历史 +

摘要

基于低温辐射计建立了一系列激光波长上光探测器响应度测量基准。进行了基准装置性能的研究,应用光辐射有效加热功率检验方法进行了不确定度评估。在氦氖、氩氪离子以及钛蓝宝石激光器的10个波长上测量了作为标准探测器的陷阱探测器的响应度。在氦氖、氩氪离子激光波长测量结果的不确定度达到0.8×10-4,在钛蓝宝石激光器达到1.1×10-4。对标准探测器的面响应均匀性、非线性、偏振响应、角度响应等特性对响应度测量结果的影响进行了研究。

Abstract

Standard of responsivity of optical detector at laser wavelengths is established based on the cryogenic radiometer.Performance of the standard facility is characterized,and the uncertainty evaluation test for the effective radiant heating power is applied.The responsivity of the standard detectors,a group of trap detectors,is measured at ten wavelengths of He-Ne,Ar+Kr+ and Ti sapphire lasers.The measurement uncertainties are 0.8×10-4 at He-Ne and Ar+Kr+ laser wavelengths and reaches 1.1×10-4 at Ti sapphire laser wavelengths.The influence of spatial non-uniformity,non-linearity, polarization dependence,angular dependence on responsivity of the standard detector is investigated.

关键词

计量学 / 辐射度 / 光电探测器 / 低温辐射计 / 响应度

Key words

Metrology / Radiometry / Optical detector / Cryogenic radiometer / Responsivity

引用本文

导出引用
林延东,吕亮. 基于低温辐射计的光探测器响应度基准[J]. 计量学报. 2012, 33(6): 494-498 https://doi.org/10.3969/j.issn.1000-1158.2012.06.04
LIN Yan-dong,Lü Liang. Responsivity Standard of Optical Detector Based on the Cryogenic Radiometer[J]. Acta Metrologica Sinica. 2012, 33(6): 494-498 https://doi.org/10.3969/j.issn.1000-1158.2012.06.04
中图分类号: TB96   

参考文献

[1]Fox N P. Radiometry with cryogenic radiometers and semiconductor photodiodes[J]. Metrologia, 1995,32(6):535-543.
[2]林延东.  低温辐射计技术及其计量学应用[M]//中国计量科学研究院.计量科学研究50年.北京:中国计量出版社,2005,839-845.
[3]Parr A C. The Candela and Photometric and Radiometric Measurements[J]. J R NIST, 2000 ,106: 151-186.
[4]Metzdorf J. Network and Traceability of the Radiometric and Photometric Standards at the PTB[J]. Metrologia, 1993, 30(4): 403-408.
[5]Gao Z Z, Wang Z C,Piao D Z, et al. Realization of the Candela by Electrically Calibrated Radiometers[J]. Metrologia, 1983,19(3): 85-92.
[6]JJG 2083-2005光谱辐射亮度、光谱辐射照度计量器具检定系统表[S].
[7]Foukal Peter V, Hoyt C, Kochling H,et al. Cryogenic absolute radiometer as laboratory irradiantce standards, remote sensing detectors, and pyrohelimoters[J] Applied Optics, 1990, 29(7): 988-993.
[8]Stock K D,Hofer H. Present state of the PTB primary standard for radiant power based on cryogenic radiometry[J]. Metrologia, 1993,30(4):291-296.
[9]林延东,吕亮,李奇. 低温辐射计光辐射有效加热功率测量的研究[J]. 计量学报, 2009, 30(6A):26-30.
[10]Livigni D J, Cromer C L,Scott T R,et al. Thermal characterization of a cryogenic radiometer and comparison with a laser calorimeter[J]. Metrologia, 1988, 35(6):819-827.
[11]Goebel R,Stock M, Khler R. Report on the international comparison of cryogenic radiometers based on transfer detectors[R]. CCPR,2000.
[12]Lopez M,hofer H, Kueck S.Measurement of the absorptance of a cryogenic radiometer cavity in the visible and near infrared[J]. Metrologia, 2005, 42(5): 400-405.
[13]Touagar O,Rougie B,Coutin J,et al. Measurement of Reflectance of the INM Cryogenic Radiometer Cavity at Several Wavelengths[J]. Metrologia,1998,35(4):387-391.
[14]林延东,姚和军,吕正. 陷光探测器偏振响应特性的研究[J]. 计量学报,2004, 25(1):23-26.
[15]吕亮,林延东. 陷阱探测器面响应均匀性的测量[J]. 计量学报,2009, 30(6A):92-94.
[16]吕亮,林延东. 硅光电二极管角度响应特性的测量[J]. 计量学报,2009, 30(6A):95-98.