通过在开封国家水大流量计量站开展DN1000口径三峡模型流道中18声道超声流量计测量准确性实验研究,得到了复杂流场给流量计引入的测量误差,验证了18声道超声流量计即使在复杂流场中依然具有较高的测量准确性。通过分析流量计得到的流速分布图可以推断出模型管道中的流场情况。流量计在正常安装位置旋转90°后测量误差变化不大,流量计测量误差和流速没有明显的相关性。采用CFD辅助设计可以增强模型实验的可靠性。
Abstract
DN1000 Three Gorges power station penstock model experiment was conducted in Kaifeng national large water flow facility to research on the measurement accuracy of 18-path ultrasonic flowmeter.The measurement errors are obtained, which verified the flowmeter had high measurement accuracy even in a complex flow field.The flow field in model penstock was inferred by analyzing the flow velocity distribution obtained from flowmeter.Measurement errors were not sensible to installation angle and average flow velocity.The reliability of the model experiment would be enhanced by using Computational fluid dynamic (CFD)-aided design.
关键词
计量学 /
三峡电站 /
模型实验 /
多声道超声流量计 /
流速分布
Key words
Metrology /
Three Gorges power station /
Model experiment /
Multi-path ultrasonic flowmeter /
Velocity distribution
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1]Gawne K D,Doering J C.Marquez Santos.Developing an Acoustic Method of Turbine Calibration[C].International Group for Hydraulic Efficiency Measurement, Montreal,Canade:1996.
[2]Wiliam Biela, Antonio E.Marquez Santos.Installation of 4 and 8-Path Acoustic Flow Meters in Guri Hydroelectric Power Plant[C].//International Group for Hydraulic Efficiency Measurement Montreal,Canade:1996.
[3]Alois Nichtawitz, Peter Grafenberger, et al.Discussion on acoustic flow measurement method[C].International Group for Hydraulic Efficiency Measurement,Lucerne,Switzerland 2004.
[4]IEC41, International Code for the Field Acceptance Test of Hydraulic Turbines[S].
[5]ASME PTC 18-2002(Revision of PTC18-1992), Hydraulic Turbines Performance Test Codes[S].
[6]孟涛,王池,陈海滨,等.用模型实验方法研究三峡电站流量计准确度[J].计量学报.2010,31(6): 509-512.