摘要

介绍了可以用于立式罐圈板半径拟合的4种方法,即加权平均法、迭代法、最小二乘法和扇形叠加等效面积法。针对同一1000m3立式罐,4种算法分析结果与国际仲裁标准围尺法测量结果的最大半径偏差分别为2.05mm、1.48mm、1.46mm和2.12mm,所有圈板平均算数偏差分别为0.97mm、0.63mm、0.62mm和1.03mm,验证了4种方法的有效性,并分析了每一种算法的特点。

Abstract

Course radius fitting algorithm is one of the key research contents of vertical tank volume measurement based on internal electro-optical distance-ranging method, which is to deduce circle equation for points set with circumferential distribution essentially. Four algorithms were introduced and analyzed, which are power mean method, iterative method, least square method and fan area superposition method. One 1000m3 vertical tank used as a test object, comparison experiment was carried out with strap method(international arbitral standard). The maximal radius error of these methods were 2.05mm, 1.48mm, 1.46mm and 2.12mm, and the absolute value of mean radius error were 0.97mm, 0.63mm, 0.62mm and 1.03mm respectively, which verifies the four methods. Applied characteristic of each method is described.

关键词

计量学 / 立式罐 / 容量计量 / 圈板半径 / 光电内测距法 / 拟合算法 / 比对试验

Key words

Metrology / Vertical tank / Volume / Course radius / Internal electro-optical distance-ranging method / Fitting algorithm / Comparison experiment

引用本文

导出引用
佟林,王金涛,刘子勇,郭立功,暴雪松,张珑. 基于光电内测法的立式罐容量计量中圈板半径拟合算法的研究[J]. 计量学报. 2011, 32(6): 522-525 https://doi.org/10.3969/j.issn.1000-1158.2011.06.09
TONG Lin,WANG Jin-tao,LIU Zi-yong,GUO Li-gong,BAO Xue-song,ZHANG Long. Study on Course Radius Fitting Algorithm for Vertical Tank Volume Measurement Based on Internal Electro-optical Distance-ranging Method[J]. Acta Metrologica Sinica. 2011, 32(6): 522-525 https://doi.org/10.3969/j.issn.1000-1158.2011.06.09
中图分类号: TB938.3   

参考文献

[1]廉育英. 容量计量技术[M]. 北京:北京计量出版,2006.
[2]廉育英, 刘子勇, 何力, 张珑. 立式金属计量罐大容量的新测量方法[J]. 计量学报,1988, 9(4):241-247.
[3]JJG 168—2005, 立式金属罐容量计量检定规程[S].
[4]OIML R71 2008, Fixed storage tanks. General requirements[S].
[5]ISO7507-1. Petroleum and liquid petroleum products-volumetic calibration of vertical cylindrical tanks[S].
[6]ISO7507-2. Petroleum and liquid petroleum products volumetric calibration of vertical cylindrical tanks part2:optical reference line method[S].
[7]ISO7505-3 2006. Petroleum and liquid prtroleum products volumetric calibration of vertical cylindrical tanks part3: optical triangulation method[S].
[8]徐国旺, 廖明潮. 拟合圆的几种方法[J]. 武汉工业学院学报, 2002, 4:104-106.
[9]傅青喜, 范勇, 习凤霞, 邵学君. 铁路罐车容积新型检定设备的研究[J]. 计量学报, 2007, 28(3A):244-246.