基于高低压电源切换的双环恒流控制电磁流量计励磁控制系统

杨双龙,王刚,徐科军,石磊,李积春

计量学报 ›› 2011, Vol. 32 ›› Issue (3) : 193-197.

PDF(379 KB)
PDF(379 KB)
计量学报 ›› 2011, Vol. 32 ›› Issue (3) : 193-197. DOI: 10.3969/j.issn.1000-1158.2011.03.01

基于高低压电源切换的双环恒流控制电磁流量计励磁控制系统

  • 杨双龙1,王刚2,徐科军1,3,石磊2,李积春2
作者信息 +

High/Low Voltage Power Switching Based on Dual-Loop Constant Current Control for Electromagnetic Flowmeter Excitation Control System

  • YANG Shuang-long1,WANG Gang2,XU Ke-jun1,3,SHI Lei2,LI Ji-chun2
Author information +
文章历史 +

摘要

为了提高电磁流量计高频方波励磁性能,基于励磁恒流控制仿真分析,采用外环高低压电源切换和内环电流微调的双环励磁恒流控制方式,以保证电磁流量计高频方波励磁时一次仪表输出信号零点稳定、电源利用效率高。设计方波励磁控制系统,以实现高频方波精确励磁。仿真结果表明,高压源电压越高越有利于拓宽励磁频率范围。实验结果表明,系统在高频方波励磁时,励磁电流响应速度快且电磁流量计传感器输出信号零点稳定。

Abstract

Based on the simulation analysis of constant excitation current control,a novel method of dual-loop control for constant excitation current control is proposed in order to improve high-frequency square wave excitation performance of the electromagnetic flowmeter. This method includes an outer loop for high/low voltage power switching and an inner loop for current fine-tuning,which can ensure zero satiability of the sensor output signal and high power efficiency of the excitation system when electromagnetic flowmeter is excited by high-frequency square wave. A square wave excitation control system is designed to realize to excite the coil by high frequency precisely. The simulation results show that the higher the high voltage power,the more widely the excitation frequency can be expanded. The experimental results show that the speed of constant excitation current control is fast and the sensor output signal of the electromagnetic flowmeter has steady zero when the excitation system is excited by high-frequency square wave.

关键词

计量学 / 电磁流量计 / 励磁控制 / 电源切换 / 双环恒流控制 / 高频励磁

Key words

Metrology / Electromagnetic flowmeter / Excitation control / Power switching / Dual-loop constant current control / High-frequency excitation

引用本文

导出引用
杨双龙,王刚,徐科军,石磊,李积春. 基于高低压电源切换的双环恒流控制电磁流量计励磁控制系统[J]. 计量学报. 2011, 32(3): 193-197 https://doi.org/10.3969/j.issn.1000-1158.2011.03.01
YANG Shuang-long,WANG Gang,XU Ke-jun,SHI Lei,LI Ji-chun. High/Low Voltage Power Switching Based on Dual-Loop Constant Current Control for Electromagnetic Flowmeter Excitation Control System[J]. Acta Metrologica Sinica. 2011, 32(3): 193-197 https://doi.org/10.3969/j.issn.1000-1158.2011.03.01
中图分类号: TB937   

参考文献

[1]蔡武昌,马中元,瞿国芳,等.电磁流量计[M].北京:中国石化出版社,2004,25-54.
[2]张涛,李斌.电磁流量计中的抗工频干扰问题[J].测控技术,2003,22(2): 65-67.
[3]李小京,王萍,卢景山.用相关算法改善电磁流量计低流速性能[J].化工自动化及仪表,2004,31(6):66-67.
[4]李斌,田才东.电磁流量计的动态响应与零点稳定性[J].自动化仪表,1991,12(9):14-18.
[5]曹金亮.多参数电磁流量计及其实现技术的研究[D].上海:上海大学,2007.
[6]马博,李兴化.电磁流量计调压式数字恒流源:中国,CN2916586Y[P].2007-06-27.
[7]Schulz R  K. Current Selsection Circuitry for Magnetic Flowmeter: US,US5639970[P]. 1997-06-17.
[8]Schweitzer J. Current-Regulator Circuit of an Electromagnetic Flowmeter: US, US6477070B2[P]. 2002-11-05.
[9]SuzukiK, Torimaru T, Ohta H. Electro-magnetic Flowmeter:US,US4663976[P].1987-05-12.
[10]小林保,黑森健一,俊藤茂,等.电磁流量计:中国,CN87101677A[P].1989-09-14.

基金

“863”计划重点项目(2008AA042207); 重庆市科学技术委员会项目(CSTC 2008AB2059)